Commissioning
Proline Promass F 500 EtherNet/IP
186
Parameter
Description
User interface / Selection
Factory setting
Configuration management
Select action for managing the device data in
the HistoROM backup.
• Cancel
• Execute backup
• Restore
• Compare
• Clear backup data
Cancel
Backup state
Shows the current status of data saving or
restoring.
• None
• Backup in progress
• Restoring in progress
• Delete in progress
• Compare in progress
• Restoring failed
• Backup failed
None
Comparison result
Comparison of current device data with
HistoROM backup.
• Settings identical
• Settings not identical
• No backup available
• Backup settings corrupt
• Check not done
• Dataset incompatible
Check not done
Function scope of the "Configuration management" parameter
Options
Description
Cancel
No action is executed and the user exits the parameter.
Execute backup
A backup copy of the current device configuration is saved from the HistoROM
backup to the memory of the device. The backup copy includes the transmitter data
of the device.
Restore
The last backup copy of the device configuration is restored from the device
memory to the device's HistoROM backup. The backup copy includes the
transmitter data of the device.
Compare
The device configuration saved in the device memory is compared with the current
device configuration of the HistoROM backup.
Clear backup data
The backup copy of the device configuration is deleted from the memory of the
device.
HistoROM backup
A HistoROM is a "non-volatile" device memory in the form of an EEPROM.
While this action is in progress, the configuration cannot be edited via the local
display and a message on the processing status appears on the display.
10.6.8 Using parameters for device administration
The
Administration
submenu systematically guides the user through all the parameters
that can be used for device administration purposes.
Navigation
"Setup" menu → Advanced setup → Administration
‣
Administration
‣
Define access code