System integration
Proline Promass F 500 EtherNet/IP
116
Description (format)
Bits
Byte
Offset
56.
Parameter 22
Configurable input assembly
Input assembly position 15
16
2
118
57.
Parameter 23
Configurable input assembly
Input assembly position 16
16
2
120
58.
Parameter 24
Configurable input assembly
Input assembly position 17
16
2
122
59.
Parameter 25
Configurable input assembly
Input assembly position 18
16
2
124
60.
Parameter 26
Configurable input assembly
Input assembly position 19
16
2
126
61.
Parameter 28
Configurable input assembly
Input assembly position 20
16
2
128
62.
Parameter 38
Sensor adjustment
Flow direction
16
2
130
63.
Parameter 40
Process parameter
Flow override
16
2
132
64.
Parameter 37
Low flow cut off
Assign process variable
16
2
134
65.
Parameter 39
Empty pipe detection
Assign process variable
16
2
136
66.
Parameter 41
Corrected volume flow calculation
Corrected volume flow calculation
16
2
138
67.
Parameter 188
Low flow cut off
On value low flow cut off
32
4
140
68.
Parameter 187
Low flow cut off
Off value low flow cutoff
32
4
144
69.
Parameter 209
Low flow cut off
Pressure shock suppression
32
4
148
70.
Parameter 191
Empty pipe detection
Low value partial filled pipe detection
32
4
152
71.
Parameter 189
Partially filled pipe detection
High value partial filled pipe detection
32
4
156
72.
Parameter 190
Empty pipe detection
Response time part. filled pipe detect.
32
4
160
73.
Parameter 182
Corrected volume flow calculation
Fixed reference density
32
4
164
74.
Parameter 186
Corrected volume flow calculation
Linear expansion coefficient
32
4
168
75.
Parameter 211
Corrected volume flow calculation
Square expansion coefficient
32
4
172
76.
Parameter 210
Corrected volume flow calculation
Reference temperature
32
4
176
77.
Parameter 183
Process parameter
Flow damping
32
4
180
78.
Parameter 184
Process parameter
Density damping
32
4
184
79.
Parameter 185
Process parameter
Temperature damping
32
4
188
80.
Parameter 5
External compensation
Pressure compensation
16
2
192
81.
Parameter 6
External compensation
Temperature mode
16
2
194
82.
Parameter 2
Medium selection
Select medium
16
2
196
83.
Parameter 3
Medium selection
Select gas type
16
2
198
84.
Parameter 119
External compensation
Pressure value
32
4
200
85.
Parameter 133
Medium selection
Temperature coefficient sound velocity
32
4
204
86.
Parameter 128
Medium selection
Reference sound velocity
32
4
208
87.
Parameter 115
Empty pipe detection
Max. damping empty pipe detection
32
4
212
88.
Parameter 241
Diagnostic settings
Alarm delay
32
4
216
89.
Parameter 58
Diagnostic behavior
Assign behavior for diagnostic
information 046
8
1
220
90.
Parameter 57
Diagnostic behavior
Assign behavior for diagnostic
information 140
8
1
221
91.
Parameter 59
Diagnostic behavior
Assign behavior for diagnostic
information 144
8
1
222
92.
Parameter 60
Diagnostic behavior
Assign behavior for diagnostic
information 374
8
1
223