12
2.1.1.2 Backside
Rear panel of HCS-4100MA/50 CMU
Rear panel of HCS-4100MA/FS/50 CMU
Rear panel of HCS-4100MB/50 and HCS-4100MC/50 CMU
Figure 2.1.2 Rear panel of HCS-4100M/50 CMU
Figure 2.1.2
14. Fiber interface
HCS-4100MA/50: multi-mode optical fiber, SC
connector;
HCS-4100MA/FS/50: single-mode optical fiber,
SC conector;
Connecting the conference main units of several
distant conference rooms to combine as one
conference room (bridging distance can reach
tens of kilometers).
15. Ethernet interface (LAN)
For communication between the conference main
unit and the PC under TCP/IP protocol to realize
remote controlling; furthermore, it enables remote
controlling by wireless touch panel through central
control system.
16. Extension interface
To connect CMU to EMU and interconnect with
audio input interface and audio output device;
devices cascadable.
17. Contribution units ring connection LED
When output works properly (
≥ 1 contribution unit
connected), LED will flash;
When no contribution unit is connected, LED is off.
18. Contribution units output interface (1-2, two
routes)
19. Video switcher interface
When cooperating with video switcher and dome
camera, auto video tracking can be realized.
20. Fire alarm linked trigger interface
+5 V voltage application:
all congress units will
be switched off and display “ALARM”;
No voltage input or too low voltage:
congress
units will return to the status preceding “ALARM”.
21. Power supply
22. Mains switch
23. “LINE OUT 2”
(RCAx2 unbalanced output)
24. “LINE OUT 1”
(3-cord XLR balanced output)
25. “LINE IN 2”
(RCAx2 unbalanced input)
26. “LINE IN 1”
(3-cord XLR balanced input)
Summary of Contents for HCS-4100MA/50
Page 50: ...35 Figure 2 1 10 Floor mode setting Normal Mode Figure 2 1 11 Floor mode setting Insert Mode...
Page 51: ...36 Figure 2 1 12 Floor mode setting Sync Line Out1 Mixer...
Page 67: ...52 Figure 3 2 6 Installation diagram of HCS 48U6SPK...
Page 80: ...65 Figure 3 3 3 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Page 81: ...66 Figure 3 3 4 Cutout of HCS 48U9 series flush mounted congress unit unit mm...
Page 82: ...67 Figure 3 3 5 Cutout of HCS 48U7MICSPK flush mounted congress unit unit mm...
Page 85: ...70 Figure 3 3 8 Installation of HCS 48U7MICSPK series flush mounted congress unit...
Page 100: ...85 3 4 2 Installation Figure 3 4 2 Cutout of HCS 48U10 series congress unit unit mm...
Page 101: ...86 Figure 3 4 3 Installation of HCS 48U10 series congress unit...
Page 162: ...147 3 10 2 Installation Figure 3 3 2 Installation of HCS 4851 50 series congress unit unit mm...
Page 163: ...148 Figure 3 3 3 Installation of HCS 4851 50 series congress unit...
Page 181: ...166 Figure 3 12 3 Installation of HCS 4325U 50 congress unit unit mm...
Page 196: ...181 Figure 3 13 7 Multi function connector connected to the HCS 4341 50 series congress unit...
Page 212: ...197 Figure 3 14 18 Multi function connector connected to HCS 4841 42 43 series congress units...
Page 225: ...210 3 16 2 Installation Figure 3 16 2 Installation of HCS 1080 electronic nameplate...
Page 275: ...260 HCS 1020 clip microphone...
Page 316: ...301 Appendix Custom made cable Appendix Dedicated 6 PIN Extension Cable...