87
3.4.3 Connection
3.4.3.1 Connecting to the CMU or the EMU
The HCS-48U10 series congress unit is equipped with
a 1.5-meter 6P-DIN cable with a standard male
connector. To connect to the HCS-4100/50 CMU or the
HCS-8300 EMU, just connect the male connector of
the first unit to the output of the main unit.
If there is a long distance between the congress unit
and the CMU (EMU), CBL6PS extension cable can be
used. One end is equipped with a 6P-DIN male
connector and the opposite end with a female
connector. Just connect the female connector of the
cable to the next congress unit, and connect the male
connector to the output of the main unit.
Figure 3.4.4 HCS-48U10 series congress unit connected
to the CMU/EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units
if “Closed Loop - Daisy Chain” connection topology is
selected. “Closed Loop - Daisy Chain” connection,
achieved by closing the loop of the daisy-chained units,
increases system reliability. To obtain “Closed Loop -
Daisy Chain” connection, just connect the last
congress unit back to the CMU or the EMU with a
CBL6PP extension cable (the cable features a 6P-DIN
male connector at each end). In HCS-4100/50 series
system, the congress main unit can realize a “Closed
Loop - Daisy Chain” connection, but only one –
extension units do not offer this feature.
Figure 3.4.5 “Closed Loop - Daisy Chain” connection
between the CMU and HCS-48U10 series congress units
3.4.3.2 Connection between congress units
All congress units of HCS-4100/50 system are
daisy-chained easily and conveniently by dedicated
6P-DIN cables.
When connecting to another congress unit, just
connect the 6P-DIN standard female connector on the
0.6-meter cable of the unit to the 6P-DIN standard male
connector on the1.5-meter cable of the next unit.
Figure 3.4.6 “Daisy-chain” connection between
HCS-48U10 series congress units
Summary of Contents for HCS-4100MA/50
Page 50: ...35 Figure 2 1 10 Floor mode setting Normal Mode Figure 2 1 11 Floor mode setting Insert Mode...
Page 51: ...36 Figure 2 1 12 Floor mode setting Sync Line Out1 Mixer...
Page 67: ...52 Figure 3 2 6 Installation diagram of HCS 48U6SPK...
Page 80: ...65 Figure 3 3 3 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Page 81: ...66 Figure 3 3 4 Cutout of HCS 48U9 series flush mounted congress unit unit mm...
Page 82: ...67 Figure 3 3 5 Cutout of HCS 48U7MICSPK flush mounted congress unit unit mm...
Page 85: ...70 Figure 3 3 8 Installation of HCS 48U7MICSPK series flush mounted congress unit...
Page 100: ...85 3 4 2 Installation Figure 3 4 2 Cutout of HCS 48U10 series congress unit unit mm...
Page 101: ...86 Figure 3 4 3 Installation of HCS 48U10 series congress unit...
Page 162: ...147 3 10 2 Installation Figure 3 3 2 Installation of HCS 4851 50 series congress unit unit mm...
Page 163: ...148 Figure 3 3 3 Installation of HCS 4851 50 series congress unit...
Page 181: ...166 Figure 3 12 3 Installation of HCS 4325U 50 congress unit unit mm...
Page 196: ...181 Figure 3 13 7 Multi function connector connected to the HCS 4341 50 series congress unit...
Page 212: ...197 Figure 3 14 18 Multi function connector connected to HCS 4841 42 43 series congress units...
Page 225: ...210 3 16 2 Installation Figure 3 16 2 Installation of HCS 1080 electronic nameplate...
Page 275: ...260 HCS 1020 clip microphone...
Page 316: ...301 Appendix Custom made cable Appendix Dedicated 6 PIN Extension Cable...