56
3.2.4 Operation
Before a meeting starts, the congress units need to be
configured by the operator, including: numbering and
testing. During the meeting, the participators use the
congress unit to sign-in, activate microphone, request
to speak, vote, etc.
3.2.4.1 Delegate unit
1. Number
First of all, make sure that the congress units are
connected properly to the CMU. All congress units
must be numbered when the system is used for the first
time or when adding or replacing congress units. The
numbering function can be activated by menu
operation on the CMU front panel or by application
software.
Select “Number” by menu operation from the CMU,
press the “MENU” key to confirm, following the system
goes to numbering status.
“Press ’1’ key of all congress
units one by one and repower”
will be displayed on the
CMU LCD. The number indicating light of all connected
congress units will blink. Press the microphone On/Off
key (“
” Sign-in/Number key for voting units) of all
congress units one by one. The number indicating light
will be deactivated. Once all congress units numbered,
restart the CMU to update the number information.
2. Sign-in
(application software needed, for
HCS-48U6DVOT series only)
To carry out voting, congress units with voting and
IC-Card reader should be registered via key press or
IC-Card. With application software, registration is
available by choosing “Seat Sign-in”.
Key-press sign-in
In key-press sign-in status, the indicating light on key
“
” will blink, press key “
” to sign-in and the
indicating light will be turned off.
IC-Card sign-in
In IC-Card sign-in status, please put the contactless
IC-card into the slot on the voting unit. If read the
IC-Card correctly, the indicating light will off after
blink. If the indicating light keeps on, stands that the
IC-Card is invalid; please read the IC-Card again or
contact the technical support.
3. Speaking
(without software, only for discussion unit
of this series)
Speaking mode is configured on the CMU. (refer to
section
2.1.4
)
A. “Open” mode
Active microphone number limitation (1/2/3/4)
NOT
reached
:
a. The microphone will be activated when the
microphone On/Off key is pressed, the speaker
can give his/her speech;
b. The microphone will be deactivated when the
microphone On/Off key is pressed again.
Active microphone number limitation (1/2/3/4)
reached
:
a. Press the microphone On/Off key to request to
speak;
b. Press the microphone On/Off key again to
cancel the request to speak;
c. When an active microphone is turned off, the
first request microphone will be activated.
B. “Override” mode
■ Active microphone number limitation (1/2/3/4)
NOT
reached
:
a. The microphone will be activated when the
microphone On/Off key is pressed, the speaker
can give his/her speech;
b. The microphone will be deactivated when the
microphone On/Off key is pressed again.
Active microphone number limitation (1/2/3/4)
reached
:
If the delegate microphone On/Off key is pressed,
its microphone will be activated and the first
Note:
When numbering, please number the
congress units one by one and do NOT press
the “NUMBER” key of several congress units
at the same time.
Summary of Contents for HCS-4100MA/50
Page 50: ...35 Figure 2 1 10 Floor mode setting Normal Mode Figure 2 1 11 Floor mode setting Insert Mode...
Page 51: ...36 Figure 2 1 12 Floor mode setting Sync Line Out1 Mixer...
Page 67: ...52 Figure 3 2 6 Installation diagram of HCS 48U6SPK...
Page 80: ...65 Figure 3 3 3 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Page 81: ...66 Figure 3 3 4 Cutout of HCS 48U9 series flush mounted congress unit unit mm...
Page 82: ...67 Figure 3 3 5 Cutout of HCS 48U7MICSPK flush mounted congress unit unit mm...
Page 85: ...70 Figure 3 3 8 Installation of HCS 48U7MICSPK series flush mounted congress unit...
Page 100: ...85 3 4 2 Installation Figure 3 4 2 Cutout of HCS 48U10 series congress unit unit mm...
Page 101: ...86 Figure 3 4 3 Installation of HCS 48U10 series congress unit...
Page 162: ...147 3 10 2 Installation Figure 3 3 2 Installation of HCS 4851 50 series congress unit unit mm...
Page 163: ...148 Figure 3 3 3 Installation of HCS 4851 50 series congress unit...
Page 181: ...166 Figure 3 12 3 Installation of HCS 4325U 50 congress unit unit mm...
Page 196: ...181 Figure 3 13 7 Multi function connector connected to the HCS 4341 50 series congress unit...
Page 212: ...197 Figure 3 14 18 Multi function connector connected to HCS 4841 42 43 series congress units...
Page 225: ...210 3 16 2 Installation Figure 3 16 2 Installation of HCS 1080 electronic nameplate...
Page 275: ...260 HCS 1020 clip microphone...
Page 316: ...301 Appendix Custom made cable Appendix Dedicated 6 PIN Extension Cable...