14. TROUBLESHOOTING
Problem
Cause
Remedy
The machine does not start
Protective hood is open
Close the protective hood
The service door of the
burner is open (HOT option)
Close the service door
The automatic work cycle
does not start
The frame is not at the
starting point
Drive the frame to starting
point of the work cycle.
The arm of the burner is not
in its lower position or the
slide of the burner is not in
rear position
Press the stop push button
of the heating operation and
drive the arm down and the
slide backwards.
The spindle is not in its
correct position
Drive the spindle into correct
position by pressing the
button a short moment, until
the pilot lamp of the spindle
position sensor B6 lights.
The pipe clamp is not closed.
Check that the dimensions of
the pipe clamp and the pipe
correspond to each other and
close the clamp.
The clamping jaw pressure
switch SP 1 does not function
Adjust the pressure switch
SP1
The arm of the burner does
not go up
The slide of the burner is not
in back position. (HOT option)
Press the heating stop
push-button and drive the
slide backwards.
The frame does not move
forward during manual
control operation
The spindle is not in correct
position
Drive the spindle into
correct position by shortly
pressing the push button,
until the pilot lamp of the
sensor indicating the spindle
position lights up.
The frame does not move
forward during the automatic
work cycle
The pressure switch SP2 does
not function (tool in starting
position for flanging)
Adjust the pressure switch
SP2
The clamp does not open in
manual operation mode
The spindle not in correct
position.
Drive the spindle into correct
position by pressing the
push-button a short moment,
until the pilot lamp of the
sensor of the spindle position
lights up