FLANGING MACHINE
23
F-200
No.
Denomination
Description of the function
20
Control display for
potentiometer
For the adjustment of the potentiometer (see chapter
6.4 Machine display and settings)
21
Reset button of the area
scanner
Resets the area scanner
22
Signal lamp of the area scanner
(OPTION)
Lamp will light, when lens of the scanner is dirty. Clean
the lens.
1. FORMING MODE SELECT SWITCH
Flanging.
Small pipe flanging
Expansion. This is used when expansion tool is used.
Welding bevel of the pipe end (OPTIONAL)
2. FORMING TYPE SELECT SWITCH
Cold forming.
Hot forming.
Flame adjustment.
Heating system is optional accessory!
3. FLANGING MODE SELECT SWITCH
1 phase flanging. This is used also for expansion.
2 phase flanging.
3 phase flanging.
Summary of Contents for F-200
Page 1: ...F 200 FLANGING MACHINE INSTRUCTION MANUAL...
Page 97: ......