Requirements of these supplies:
Compressed air
0,6 MPa
Oxygen
0,4--0,6 MPa
Propane
0,20 MPa
These supplies should be provided with pressure regulators.
NOTE!
¨
If there’s a danger that particles will get loose from the inside of the
heating gas or oxygen pipes, the operation of the valves must be assured by
installing a filter in the heating gas and oxygen feed line (filtering at least 50µm).
E.g. Krom Schroder GFK 20 (propane).
Main gas valves
Machine is equipped with main gas valves for oxygen and propane. Gas supplies are
connected to these valves. There are also pressure regulators for gas on these valves.
Main gas valves