INSTRUCTION MANUAL
18
5.3 CONNECTION OF THE MACHINE TO THE SOURCES OF ENERGY
5.3.1 CONNECTION TO THE ELECTRIC NETWORK
a
DANGER! Disconnect the electric current to the supply cable before
starting to carry out the connection - fatally dangerous voltage.
a
DANGER! Even if the main switch is in “0” (OFF) position, the switch as
well as the supply cable still are alive - fatally dangerous voltage!
a
DANGER! Only a qualified and authorized person is allowed to carry out
the connection of the F-200 machine to the mains.
The terminals for connection of the external supply cable of the F-200 machine are
located in the electric box. Pay special attention to the correct earthing of the machine.
Check that the working voltage indicated on the machine and the supply voltage
coincide. Also check that the current value of the overload circuit breakers corresponds
to the current value of the motors. The machine can be supplied for a voltage range of
200-240V/50Hz/60Hz and of 380V-480/50Hz/60Hz. Check the correct connection with
the help of the circuit diagram delivered with the machine. This circuit diagram will be
found in the pocket of the electric box door. Compare the diagram with the nameplate of
the machine.
NOTE!
¨
If the residual- current circuit breaker is wanted to use with machine
power supply system, a pulsating DC type (type A) is recommended to be used.
5.3.2 CONNECTION TO THE COMPRESSED AIR SYSTEM
L
DANGER! The connection of the F-200 machine to the compressed air system
as well as to the propane and oxygen supply is to be performed only by a person
authorized to this effect by the employer.
The heating equipment demands the machine to be connected to a compressed air
system. Moreover an oxygen supply and a propane supply are required.
Compressed air connection and regulator
Summary of Contents for F-200
Page 1: ...F 200 FLANGING MACHINE INSTRUCTION MANUAL...
Page 97: ......