INSTRUCTION MANUAL
40
8. Select the correct buffer plates according to the wall-thickness of the pipe and position
of the forming tool housing.
S=wall-thickness of pipe, N=thickness of buffer plate.
X=adjustment factor depending of forming tool housing position.
Cold flanging: S ≤ N ≤ S+2 →
Hot flanging: S+2 < N ≤ 2xS →
Valid with 2.5 radius setting. Marks in housing
Select a 10mm buffer plate
Select a 10mm buffer plate
Select a 10mm buffer plate
If pin housing is rotated compensate buffer plate thickness correspondingly.
The thickness of the buffer plate is stamped on the plate itself.
9. Loosen the fixing screw and draw out the pin with the buffer plate. Install buffer plates
of the correct thickness on both sides and lock them in this position with the fixing screw.
10. Start the machine by pressing the power on push-button
.
11. Close the clamping jaws by turning the clamp control
switch. Make sure the jaw
does not cut into the guides of the pipe clamp.
12. Insert the locking pins into the pipe clamping jaws.
13. Open the clamping jaws by turning the clamp control switch.
If housing is rotated to +direction, more than 36° (1mm) reduce plate thickness by 1mm.
If housing is rotated to –direction more than 18° (0,5mm) add 1mm to plate thickness.
After that add 1mm to every 36° to –direction.
Summary of Contents for F-200
Page 1: ...F 200 FLANGING MACHINE INSTRUCTION MANUAL...