1. PCM (ECM)
2. PCM (ECM) connector
(Viewed from harness side)
1.2 mm
4.6 mm
6-26
ENGINE DIAGNOSIS (RHZ ENGINE WITH SINGLE-CONNECTOR ECM)
6) Install ECM cover (1) to ECM connector and tighten screw (5).
7) Install harness cover (2) to ECM connector assembly (3) by fas-
tening clamp (4) and then lock ECM connector using lock lever
(6).
NOTE:
When clamp replacement is necessary, be sure to use a
clamp with width and thickness as specified below or less.
If a larger clamp is used, lock lever will be caught by clamp
and it will be impossible to install ECM connector to ECM.
Width: 4.6 mm
Thickness: 1.2 mm
8) Install ECM to bracket referring to “ENGINE CONTROL MOD-
ULE” in this section.