58
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
Storage Automated Diagnostics Environment
linktest
Test
Output
running on diag221.central.sun.com
linktest started on FC interconnect: fp to switch2
qlctest started on hba port
"qlctest: called with options:
dev=/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl|
run_connect=Yes| selftest=Disable| mbox=Disable| checksum=Disable|
ilb_10=Disable| ilb=Disable| elb=Enable| iterations=100| xcnt=65536|
selectpattern=critical| userpattern=0x7e7e7e7e"
"qlctest: Started."
"Program Version is 4.0.1"
"Testing qlc0 device at
/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl."
"QLC Subsystem ID = 0x106"
09/13/02 13:52:23 diag226.Central.Sun.COM MSGID 6028
qlctest.port_online.FATAL : "ERROR: Didn’t detect loop as being online
and user selected external loopback option.
Return code from checking path
/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl was 131337
"
qlctest failed
error code: 256
Remove FC Cable from hba:
/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl
Insert FC Loopback Cable into hba:
/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl
Continue Isolation ?
qlctest started on hba port
"qlctest: called with options:
dev=/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl|
run_connect=Yes| selftest=Disable| mbox=Disable| checksum=Disable|
ilb_10=Disable| ilb=Disable| elb=Enable| iterations=100| xcnt=65536|
selectpattern=critical| userpattern=0x7e7e7e7e"
"qlctest: Started."
"Program Version is 4.0.1"
"Testing qlc0 device at
/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl."
"QLC Subsystem ID = 0x106"
"QLC Adapter Chip Revision = 1, Risc Revision = 4,
Frame Buffer Revision = 1287, Riscrom Revision = 1,
Driver Revision = 6.0-2-1.17 "
... (
continued
)
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...