102
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
5. Start Testing FRUS.
■
Storage Automated Diagnostic Environment version 2.1 tests, such as the
brocadetest
(1M),
qlctest
(1M),
t3test
(1M),
linktest
(1M), and
a5ktest(1M).
■
Brocade CLI tests (
loopPortTest
,
spinFab
,
crossPortTest
)
■
Sun StorEdge T3 Array tests, such as
T3OFDG
(1M)
■
Sun StorEdge A3500FC arrays Healthcheck
Note –
The conclusion of these tests isolate the problem to a FRU to be replaced.
Follow the appropriate hardware manual for proper FRU replacement procedures.
6. Verify the fix.
■
/var/adm/messages
(path online, multipath informational messages)
■
Storage Automated Diagnostic Environment version 2.1 status
■
Sun StorEdge Traffic Manager or VxDMP, to return the path to its normal state