Appendix B
Brocade Communications Systems Switch Troubleshooting
93
CODE EXAMPLE B-6
loopPortTest Example Output
Note –
Notes on
loopPortTest
■
Syntax is
loopporttest
<num_passes>,<port>,<user_pattern>,<pattern_width>
■
Only works on logged in L-Ports
■
To test ports with Loopback connectors, use crossPortTest
CODE EXAMPLE B-7
spinFab Example Output
diag164:admin> loopporttest 100,2,0x7e7e7e7e,4
Configuring L-port 2 to Cable Loopback Port........done.
Will use pattern: 7e7e7e7e
7e7e7e7e
7e7e7e7e
7e7e7e7e
Running Loop Port Test ........ passed.
Configuring Loopback L-port(s) back to normal L-
port(s).........done.
diag167:admin> spinfab 1,0,0
spinFab0 running...
spinFab0: Completed 1 megs, status: passed.
port 0 test status: 0x00000000 -- passed.