62
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
2. Issue the
luxadm display
command to the affected Sun StorEdge T3+ array LUN.
Refer to the original Storage Automated Diagnostic Environment email alert for the
LUN ID.
The
luxadm display
command output indicates that both paths to the Sun
StorEdge T3+ array LUN are seen again. However, the array is still using the
secondary paths for the I/O data stream (secondary path is ONLINE; primary path
is STANDBY).
# luxadm display /dev/rdsk/c9t60020F20000003D53D349365000C1691d0s2
DEVICE PROPERTIES for disk: /dev/rdsk/c9t60020F20000003D53D349365000C1691d0s2
Status(Port A):
O.K.
Status(Port B):
O.K.
Vendor:
SUN
Product ID:
T300
WWN(Node):
50020f20000003c5
WWN(Port A):
50020f23000003d5
WWN(Port B):
50020f23000003c5
Revision:
0201
Serial Num:
Unsupported
Unformatted capacity:
51203.250 MBytes
Write Cache:
Enabled
Read Cache:
Enabled
Minimum prefetch:
0x0
Maximum prefetch:
0x0
Device Type:
Disk device
Path(s):
/dev/rdsk/c9t60020F20000003D53D349365000C1691d0s2
/devices/scsi_vhci/ssd@g60020f20000003d53d349365000c1691:c,raw
Controller
/devices/pci@1f,2000/SUNW,qlc@1/fp@0,0
Device Address
50020f23000003d5,0
Class
primary
State
STANDBY
Controller
/devices/pci@4,2000/SUNW,qlc@1/fp@0,0
Device Address
50020f23000003c5,0
Class
secondary
State
ONLINE
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...