Appendix B
Brocade Communications Systems Switch Troubleshooting
107
FIGURE B-3
Storage Automated Diagnostic Environment Alert
This alert shows:
■
An error on port two of switch
172.20.67.167
occurred
■
A Sun StorEdge Traffic Manager offline event occurred
■
The HBA is offline
[continued from previous page]
Site : Lab Broom
Source : diag229.central.sun.com
Severity : Error (Actionable)
Category : HOST DeviceId : host:diag229.central.sun.com
EventType: AlarmEvent.M.lun.T300.c3t50020F23000068CCd1s2.statusA
EventCode: 7.5.27
EventTime: 2002/07/11 10:35:08
The state of ’lun.T300.c3t50020F23000068CCd1s2.statusA’ on diag229.central.sun.com
changed from ’O.K.’ to ’Missing’ (target=t3:t3-67-166/172.20.67.166)
INFORMATION:
luxadm display reported a change in the port-status of one of it’s
paths. The agent then tries to find which enclosure this path corresponds to
by reviewing it’s database of T3’s and VE’s.
luxadm display 2a00006022004188
DEVICE PROPERTIES for disk: 2a00006022004188
Status(Port A): O.K. **** monitoring this field.
Vendor: SUN
Product ID: SESS01
WWN(Node): 2a00006022004188
WWN(Port A): 2b00006022004188
Revision: 080D
Serial Num: Unsupported
Unformatted capacity: 241724.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c7t2B00006022004188d0s2
/devices/sbus@8,0/SUNW,qlc@1,30000/fp@0,0/ssd@w2b00006022004188,0:c,raw
----------------------------------------------------------------------
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...