108
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
2. Determine the extent of the problem using
cfgadm -al
output.
CODE EXAMPLE B-9
cfgadm -al
output to check OS level fabric condition
The device on c3 has disappeared. In addition, the
luxadm
output of the Sun
StorEdge T3 arrays shows the following.
# cfgadm -al
c3
fc-fabric
connected
configured
unknown
c3::50020f23000068cc
unavailable
connected
configured
unusable
c4
fc-private
connected
unconfigured
unknown
c5
fc-fabric
connected
configured
unknown
c5::210000e08b05041c
unknown
connected
unconfigured
unknown
c5::50020f2300004331
disk
connected
configured
unknown
# luxadm display /dev/rdsk/c6t60020F2000003EE53AAF7A09000DA257d0s2
/: luxadm display 50020f23000068cc
Error: Invalid pathname (50020f23000068cc)
/:
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...