60
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
... (
continuation
)
switch2test failed
error code: 256
Remove FC Loopback Cable from switch2: 100000c0dd00bfda
(sw-67-84), port: 0
Insert a NEW FC GBIC or SFP into switch2: 100000c0dd00bfda
(sw-67-84), port: 0
Insert FC Loopback Cable into switch2: 100000c0dd00bfda (sw-67-84),
port: 0
Continue Isolation ?
switch2test started on switch2 100000c0dd00bfda port 0
"Called with options: dev=0:172.20.67.84:| passwd=x|
selectpattern=critical| userpattern=0x7e7e7e7e"
"switch2test: Started."
"Connected to 172.20.67.84"
"Switch Model type is: SANbox2-16"
"Power and Fans are okay"
"Detected a loopback plug inserted onto this port"
"Get original port counters for port 0"
"Detected port type Not Initialized"
"External loopback test passed"
"Get port counters after testing for port 0"
"Compare of port counters passed"
"Test Passed"
switch2test completed successfully
error code: 0
Remove FC Loopback Cable from switch2: 100000c0dd00bfda
(sw-67-84), port: 0
Restore ORIGINAL FC Cable into switch2: 100000c0dd00bfda
(sw-67-84), port: 0
Suspect ORIGINAL FC GBIC or SFP in switch2: 100000c0dd00bfda
(sw-67-84), port: 0
Retest to verify FRU replacement.
linktest completed on FC interconnect: hba to switch2
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...