Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
CODE EXAMPLE B-4
diagShow
Example Output
CODE EXAMPLE B-5
crossPortTest
Example Output
The "1000" is the number of passes, the "1" denotes singlePortAlso mode, which
allows the test to be run on a single port with a loopback connector plug inserted
diag167:admin> diagshow
nTicks: 0, Max: 4473924
Diagnostics Status: Tue Mar 19 14:04:30 2002
port#: 0 1 2 3 4 5 6 7
diags: OK OK OK OK OK OK OK OK
state: UP DN UP DN DN DN UP UP
pt0: 4086880 frTx 64382622 frRx 0 LLI_errs.
pt2: 38616950 frTx 300398 frRx 12 LLI_errs.
pt6: 28852033 frTx 235091315 frRx 111 LLI_errs.
pt7: 331090679 frTx 8930476 frRx 31 LLI_errs.
Central Memory OK
Total Diag Frames Tx: 8318
Total Diag Frames Rx: 8911
diag167:admin> crossporttest 1000,1
Running Cross Port Test ....... passed.
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...