118
Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
The primary path is now restored as the ONLINE path and I/O is again using this
path. As a final check, look to the Storage Automated Diagnostic Environment
version 2.1 topology. The ports that were in error are now green and the [mpx] error
is green as well, as shown in
# luxadm failover primary
/home/mckenney/ws/storade2.2/StorTools/tests/discover: luxadm display
50020f23000068cc
DEVICE PROPERTIES for disk: 50020f23000068cc
Status(Port A): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f20000068cc
WWN(Port A): 50020f23000068cc
Revision: 0200
Serial Num: Unsupported
Unformatted capacity: 119514.500 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c3t50020F23000068CCd0s2
/devices/pci@9,600000/pci@2/SUNW,qlc@5/fp@0,0/ssd@w50020f23000068cc,0:c,raw
DEVICE PROPERTIES for disk: 50020f23000068cc
Status(Port B): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f20000068cc
WWN(Port B): 50020f23000068cc
Revision: 0200
Serial Num: Unsupported
Unformatted capacity: 119514.500 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c3t50020F23000068CCd1s2
/devices/pci@9,600000/pci@2/SUNW,qlc@5/fp@0,0/ssd@w50020f23000068cc,1:c,raw
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...