Chapter 4
Troubleshooting Example
51
... (
continuation
)
DETAILS:
Sep 13 13:05:36 WWN:50020f23000003d5 diag226.Central.Sun.COM mpxio: [ID
779286 kern.info] /scsi_vhci/ssd@g60020f20000003d53d34940b0004e6b6 (ssd0)
multipath status: degraded, path /pci@1f,2000/SUNW,qlc@1/fp@0,0 (fp4) to target
address: 50020f23000003d5,3 is offline
Sep 13 13:05:36 WWN:50020f23000003d5 diag226.Central.Sun.COM mpxio: [ID
779286 kern.info] /scsi_vhci/ssd@g60020f20000003d53d3493d80003c090 (ssd1)
multipath status: degraded, path /pci@1f,2000/SUNW,qlc@1/fp@0,0 (fp4) to target
address: 50020f23000003d5,2 is offline
Sep 13 13:05:36 WWN:50020f23000003d5 diag226.Central.Sun.COM mpxio: [ID
779286 kern.info] /scsi_vhci/ssd@g60020f20000003d53d3493930006a222 (ssd2)
multipath status: degraded, path /pci@1f,2000/SUNW,qlc@1/fp@0,0 (fp4) to target
address: 50020f23000003d5,1 is offline
Sep 13 13:05:36 WWN:50020f23000003d5 diag226.Central.Sun.COM mpxio: [ID
779286 kern.info] /scsi_vhci/ssd@g60020f20000003d53d349365000c1691 (ssd3)
multipath status: degraded, path /pci@1f,2000/SUNW,qlc@1/fp@0,0 (fp4) to target
address: 50020f23000003d5,0 is offline
----------------------------------------------------------------------
Site : FSDE LAB Broomfield CO
Source : diag226.central.sun.com
Severity : Warning (Actionable)
Category : HOST DeviceId : host:diag226.central.sun.com
EventType: AlarmEvent.M.hba
EventCode: 7.5.20
EventTime: 2002/09/13 13:06:49
DESCRIPTION: status of hba /devices/pci@1f,2000/SUNW,qlc@1/fp@0,0:devctl on
diag226.central.sun.com changed from CONNECTED to NOT CONNECTED
INFORMATION:
monitors changes in the output of luxadm -e port
Found path to 20 HBA ports
/devices/sbus@2,0/SUNW,socal@d,10000:0 NOT CONNECTED
.....
RECOMMENDED-ACTION:
use ’luxadm -e port’ to confirm hba status, verify if all paths are working
... (
continued
)
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...