Sun StorEdge SAN 4.0 Release Field Troubleshooting Guide • October 2002
DIAG-POST-SKIPPED
Err #0004
[switch initialization]
POST is skipped. Its message
recommended that POST be
executed.
Informational only
None required
DIAG-REGERR
Err#0B15, 0415
[portRegTest,
sramRetentionTest]
Data read from ASIC register
or ASIC SRAM did not match
data previously written into
same location
ASIC failure
Replace mainboard
assembly
DIAG-REGERR_URST
Err#0B16, 0416
[portRegTest,
sramRetentionTest]
Port failed to unreset
ASIC failure
Replace mainboard
assembly
DIAG-STATS
Err#2660-2662-, 3060-
3062
[portLoopback Test,
crossPortTest]
Port counter value did not
match the number of frames
actually transmitted. Possible
counters reporting:
• FramesTx—number of
frames transmitted
• FramesRx—number of
frames received
• CI3FrmRx—number of
Class 3 frames received
ASIC, SFP module
or fiber cable failure
Replace mainboard
assembly, SFP module
or fiber cable
DIAG-TIMEOUT
Err#266F, 306F, 386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
For portLoopbackTest and
crossPortTest:
Port failed to receive frame
within timeout period
For centralMemoryTest:
Port failed to detect an
interrupt within the timeout
period.
ASIC, SFP module
or fiber cable failure
Replace mainboard
assembly, SFP
module, or fiber cable
DIAG-XMIT
Err#2271, 2671, 3071,
3871
[portLoopbackTest,
crossPortTest, spinSilk,
camTest]
Port failed to transmit frame
ASIC failure
Replace mainboard
assembly
CONFIG CORRUPT
The switch configuration
information has become
irrevocably corrupted.
OS error
The system
automatically resorts
to the default
configuration settings.
TABLE C-3
Diagnostic Error Messages (Continued)
Message
Description
Probable Cause
Action
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...