Appendix C
Brocade Communications Systems Error Messages
129
DIAG-CAMSID
Err#223C
[camTest]
ASIC failed SID NO
translation test
ASIC failure
Replace mainboard
assembly
DIAG-CLEAR_ERR
Err#0001
Port’s diag error flag (OK or
BAD) is cleared
Information only
None required
DIAG-CMBISRF
Err#1021
[centralMemoryTest]
ASIC’s Central Memory
SRAMs did not complete the
BISR within the timeout
period
ASIC failure
Replace mainboard
assembly
DIAG-CMBISRTO
Err#1020
[centralMemoryTest]
ASIC’s Central Memory
SRAMs did not complete the
BISR within the timeout
period
ASIC failure
Replace mainboard
assembly
DIAG-CMERRPTN
Err#102B
[centralMemoryTest]
Error detected at the wrong
port
ASIC failure
Replace mainboard
assembly
DIAG-CMERRTYPE
Err#102A
[centralMemoryTest]
Port got the wrong CMEM
error type
ASIC failure
Replace mainboard
assembly
DIAG-CMICKSUM
Err#2036
[cmiTest]
CMI message received failed
bad checksum test.
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMIDATA
Err#2035
[cmiTest]
CMI data received but did
not match data transmitted
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMIINVCAP
Err#2034
[cmiTest]
Unintended ASIC
erroneously got CMI capture
flag
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMINOCAP
Err#2033
[cmiTest]
CMI intended receiver ASIC
failed to get CMI capture flag.
ASIC or mainboard
failure.
Replace mainboard
assembly
DIAG-CMISA1
Err#2032
[cmiTest]
An attempt to send a CMI
message from ASIC to ASIC
failed.
ASIC failure
Replace mainboard
assembly
DIAG-CMNOBUF
Err #1029
[centralMemoryTest]
Port could not get any buffer
ASIC failure
Replace mainboard
assembly
TABLE C-3
Diagnostic Error Messages (Continued)
Message
Description
Probable Cause
Action
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...