Appendix B
Brocade Communications Systems Switch Troubleshooting
117
6. Verify the fix.
a. Check the
cfgadm
output to see if the device appears back in the fabric.
CODE EXAMPLE B-10
c
fgadm
Output
The c3 device is connected.
b. Check the status of the device with the
luxadm failover
command.
# cfgadm -al
c3
fc-fabric
connected
configured
unknown
c3::50020f23000068cc
disk
connected
configured
unusable
c4
fc-private
connected
unconfigured
unknown
c5
fc-fabric
connected
configured
unknown
c5::210000e08b05041c
unknown
connected
unconfigured
unknown
c5::50020f2300004331
disk
connected
configured
unknown
Summary of Contents for StorEdge