Appendix C
Brocade Communications Systems Error Messages
131
DIAG-LCMEMTX
Err#1F27, 1028
[centralMemoryTest]
Central Memory transmit
path failure: ASIC 1 failed to
read ASIC 2 via the transmit
path
mainboard failure
Replace mainboard
assembly
DIAG-LCMRS
Err#1F25, 1025
[centralMemoryTest
cmemRetentionTest]
Central Memory Read Short:
M bytes requested but got
less than M bytes
ASIC failure
Replace mainboard
assembly
DIAG-LCMTO
Err#1F267, 1026
[centralMemoryTest,
cmemRetentionTest]
Central Memory Timeout:
Data transfer initiated, did
not complete within the
timeout period.
ASIC failure
Replace mainboard
assembly
DIAG-MEMNULL
Err#0112
[ramTest]
Test failed to malloc.
mainboard failure
Replace mainboard
assembly
DIAG-MEMSZ
Err#0111
[ramTest]
Memory size to be tested is
less than or equal to zero
mainboard failure
Replace mainboard
assembly
DIAG-MEMORY
Err#0110
[ramTest]
Data read from RAM location
did not match previously-
written data into same
location.
CPU RAM failure
Replace mainboard
assembly or DRAM
module
DIAG-PORTABSENT
Err#2670, 3070, 3870
[portLoopbackTest,
crossPortTest, spinSilk]
Port is not present
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-PORTDIED
Err#265F, 305F, 385F
[portLoopbackTest,
crossPortTest, spinSilk]
Port was in loopback mode
and then went inactive
ASIC, SFP module
or fiber cable failure
Replace mainboard
assembly, SFP
module, or fiber cable
DIAG-PORTSTOPPED
Err#3874
[spinSilk]
Port is no longer
transmitting, as indicated by
the Number Of Frames
Transmitted counter being
stuck at N frames.
ASIC, SFP module,
or fiber cable failure.
Replace mainboard
assembly, SFP
module, or fiber cable.
DIAG-PORTWRONG
Err#3078
[crossPortTest]
Frame erroneously received
by port M instead of the
intended port N
ASIC failure
Replace mainboard
assembly
TABLE C-3
Diagnostic Error Messages (Continued)
Message
Description
Probable Cause
Action
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...