Page 3: ...ittstelle R und RS485 12 4 3 RS485AC Schnittstellen 14 4 4 Twisted Pair Schnittstelle TWP 14 4 5 LWL Schnittstellen für Multimode Faser 15 4 6 LWL Schnittstellen für Singlemode Faser 16 5 Was tun bei Problemen 16 6 Safety Instructions 17 6 1 Warnings and Instructions 17 6 2 Installation 17 6 3 To ensure Electro magnetic compatibility 17 6 4 Ventilation 17 6 5 Temperature 17 6 6 Re configuration of...

Page 4: ...mode fibers 26 9 6 Optic fiber interface modules for single mode fibers 27 10 Troubleshooting 27 11 Technical Specifications 28 12 CE Declaration of Conformity 31 13 Contact 31 14 Warranty 31 15 Support 32 16 Order information 32 16 1 SH ARC PCIu cards 32 16 2 SH ARC PCIe cards 33 16 3 SH ARC PCI104 card 33 16 4 Interface modules type PC104 34 17 Literature 34 4 ...

Page 5: ...rf nur in PCs mit Gehäusen gemäß EN 60950 1 eingebaut und betrieben werden 1 3 Elektromagnetische Verträglichkeit a An den ARCNET Anschlüssen dürfen nur geschirmte Kabel mit geschirmten Steckern angeschlossen werden b Es dürfen nur Bitraten verwendet werden die von SOHARD für das gewählte Übertragungsverfahren spezifiziert sind c Bei modularen Geräten dürfen nur originale Schnittstellenmodule von ...

Page 6: ...ommt der Baustein COM20022 zum Einsatz Die PCI Karten haben einen 32 Bit breiten Datenbus die PCI Express Karten sind über Single Lane an den Bus angebunden Beides ermöglicht eine verzögerungsfreie ARCNET Übertragung Die PC Karten mit koaxialer oder EIA 485 ARCNET Schnittstelle sind Einzelplatinen Die anderen Varianten u a mit optischen Schnittstellen sind in Sandwich Bauweise ausgeführt Bei der S...

Page 7: ...f Die SH ARC PCIe SH ARC PCIu und SH ARC PCI104 werden vom BIOS des Systems automatisch in den I O und Memory Bereich eingeblendet Über Betriebssystemfunktionen können dann die reservierten Ressourcen erfragt werden Die hierfür erforderlichen PCI Parameter sind DEVICE ID VENDOR ID CLASS CODE SUBSYSTEM ID SUBSYSTEM VENDOR ID 0x9030 0x10B5 0x0280 0x2978 0x10B5 Bei Verwendung der SOHARD Treiber werde...

Page 8: ...ster implementiert Alle anderen Register sind unverändert 8 Bit breit Daher sind die 8 höherwertigen Bits bei bei 16 Bit Zugriffen auf diese Register ohne Bedeutung Die PCI Base Adresse 2 und 5 sind für eine besonders schnelle Datenübertragung vom PC zur SOHARD ARCNET Karte vorgesehen Der SOHARD Treiber unterstützt diese Betriebsart Wenn Sie diesen Modus für eigene Anwendungen nutzen möchten wende...

Page 9: ...e Schreib Lese Zugriffe des Host PC auf die Karte an Coax grün Die LED ist aktiviert wenn der ARCNET Controller für eine Bitrate 2 5 Mbit s konfiguriert ist der Controller sendeseitig aktiv ist und der eingestellte Modus dem Defaultwert Non Backplane entspricht Wenn die LED aus ist wird die Koaxial Schnittstelle nicht angesteuert Anmerkung der derzeit verwendete Transceiver erlaubt nur den Betrieb...

Page 10: ...gsspannungen anzeigen Die überwachten Spannungen sind auf der Leiterplatte aufgedruckt 3 6 2 LEDs der SH ARC PCI104 LED Beschreibung PC Aktivität rot Die LED zeigt alle Schreib Lese Zugriffe des Host PC auf die SH ARC PCI104 Karte an Spannungs versorgung grün Die LED1 zeigt das Vorhandensein der 5 V an die LED2 das der 3 3 V Die LEDs zeigen nicht an ob die Versorgungsspannungen den Anforderungen d...

Page 11: ...Koaxialkabels Die Schnittstelle wird nur aktiviert wenn sowohl eine zulässige Bitrate 2 5 10 Mbit s eingestellt ist als auch der Controller COM20022 im Non Backplane Mode betrieben wird Die Schnittstelle ist für den Betrieb an einem Koaxialkabel RG 62 vorgesehen Bei den Karten SH ARC PCIe K und SH ARC PCIu K muss im Bedarfsfall eine Terminierung extern angeschlossen werden z B mittels eines T Stüc...

Page 12: ...ei der Auslieferung ist die Terminierung effektive Impedanz ca 115 Ohm nicht aktiviert Der Leitungswellenwiderstand des verwendeten Kabels sollte diesem Wert möglichst gut entsprechen damit keine Reflexionen auftreten Ggf ist eine externe Terminierung zu verwenden DIP Schalter Schalter 1 Schalter 2 Funktion Bemerkung ON ON Leitungsabschluss für RS485 aktiviert OFF OFF Kein Leitungsabschluss für RS...

Page 13: ...TA A Datenleitung A 4 DATA B Datenleitung B 2 6 8 NC Reserviert 9 5V_RS Galvanisch getrennte 5 V für RS 485 Schnitt stelle Die Stroment nahme darf 25 mA nicht überschreiten Schirm AGND Schirm AGND ist das Halteblechpotenzial GND_RS ist die Masse des galvanisch getrennten RS 485 Schaltungsteils Terminierung und Fail Safe Schaltung stellen sich wie folgt dar Der resultierende Abschlusswiderstand bet...

Page 14: ... Bedeutung 4 Phase B Datenleitung B 5 Phase A Datenleitung A 1 3 6 9 unbeschaltet Reserviert 4 3 2 RS485AC BNC RS485AC BNC Anschluss BNC Buchse galvanisch getrennt keine interne Terminierung Der Innenleiter ist mit Phase A der Außenleiter mit Phase B verbunden 4 4 Twisted Pair Schnittstelle TWP Wichtiger Hinweis Zur Erhaltung der elektromagnetischen Verträglichkeit EMV muss das verwendete Kabel üb...

Page 15: ...s zu vermeiden Bei größeren Entfernungen und oder Kabeln hoher Dämpfung sollte eine mittlere oder hohe Leistung eingestellt werden Schalter 1 Schalter 2 Opt Ausgangsleistung Bemerkung OFF OFF sehr niedrig OFF ON niedrig Voreinstellung ON OFF mittel ON ON hoch Wichtiger Hinweis Wenn kein LWL Kabel angeschlossen ist muss der Empfängeranschluss abgedeckt werden da sonst Fremdlicht aus Leuchtstoffröhr...

Page 16: ...ngen TX muss mit RX bzw RX mit TX der Gegenstelle verbunden werden 5 Was tun bei Problemen Die Karte ist ansprechbar aber es werden keine Interrupts generiert Mögliche Ursache Im BIOS Setup des Rechners sind nicht genügend Interrupt Kanäle für PCI reserviert Abhilfe Im BIOS Setup weitere Interrupts für PCI aktivieren Die Receive LED zeigt Rekonfigurationen an Mögliche Ursachen Es ist nur ein Knote...

Page 17: ...vironments It must only be mounted in and operated within PCs with casings according to EN 60950 1 6 3 To ensure Electro magnetic compatibility a Only attach shielded cables and shielded connectors to the ARCNET connector b Only use bit rates which are specified by SOHARD for the actual transfer mode c Only use original interface modules by SOHARD for modular cards d Only use PC casings with intac...

Page 18: ... 32bit wide data bus the PCI Express cards are connected thru Single Lane to the PCI Express bus Both assure instantaneous ARCNET transmissions The PC cards with coaxial or RS 485 interface are single board cards The other variants i a those featuring optical interfaces are compound cards built like sandwiches The PCI 104 card requires an additional ARCNET Interface module 8 Function 8 1 Setting t...

Page 19: ...e SH ARC PCIe SH ARC PCIu and SH ARC PCI104 are automatically mapped into the I O and memory space by the BIOS of the system The resources reserved can be determined by using functions of the operating system The PCI parameters are as follows DEVICE ID VENDOR ID CLASS CODE SUBSYSTEM ID SUBSYSTEM VENDOR ID 0x9030 0x10B5 0x0280 0x2978 0x10B5 When SOHARD drivers are applied the card will be automatic...

Page 20: ... implemented for the data register All other registers will have 8 bit size Thus the 8 MSBs will be without significance for 16 bit accesses PCI base address 2 and 5 are provided for fast data transfer between the host and the SOHARD ARCNET card The SOHARD drivers support this mode In case you wish to use this mode for applications of your own you are kindly asked to contact the manufacturer 8 4 S...

Page 21: ...This LED is activated if the ARCNET controller is configured for a bit rate 2 5 Mbit s the controller is transmitting and in default mode non Backplane When the LED is inactive no data are sent via the coax interface Note The HIT is specified only for operation at 2 5 Mbit s Receive yellow The LED indicates any activity on the ARCNET receiving channel As both the coaxial and the RS 485 interface r...

Page 22: ...st Power LEDs green LED1 indicates the presence of a 5 V supply LED2 that of 3 3 V The LED do not show whether the voltages fulfill the requirements of the card and the interface module LED4 green This LED is activated when a coaxial interface module is applied and when a bit rate valid for such modules is configured Otherwise coaxial interfaces are not being accessed 8 6 3 LEDs of the interface m...

Page 23: ...C plug With the ARCNET interface modules the 93 ohm termination can be switched to the coaxial line through the dual DIP switch By default the termination is switched off Dual DIP switch Switch 1 Switch 2 Function Remarks ON ON Coaxial line termination active OFF OFF Coaxial line termination inactive presetting ON OFF Invalid OFF ON Invalid Connector type BNC socket galvanically isolated 9 2 RS 48...

Page 24: ...interface module supports all data rates up to 10 Mbit s Important To maintain the electro magnetic compatibility EMC the shield of the cable connected to the D sub DE9M plug must be solidly attached to the screen of the connector Pin assignment is compatible to all RS 485 interfaces by SOHARD Connector type 9 pin D sub female Pin assigment Pin Marking Description 1 5 GND_RS Reference potential su...

Page 25: ...ohm 9 3 RS485AC Interface Important To maintain the electromagnetic compatibility EMC the shield of the cable connected to the RJ45 plug must be solidly attached to the shield of the connector 9 3 1 RS485AC RJ45 RS485AC RJ45 Connector type RJ45 socket Pin assignment RJ45 Pin Marking Description 4 Phase B Data line B 5 Phase A Data line A 1 3 6 9 NC Reserved 25 ...

Page 26: ...gnment Pin Transceiver Pin Description 4 Phase A Data line A 5 Phase B Data line B 1 3 6 9 NC Reserved 9 5 Optic fiber interface modules for multi mode fibers 9 5 1 Setting the transmission power The optical output power of the transmitter can be adjusted in four steps Low power is recommended for short fiber lines with low loss in order to avoid long recovery times of the receiver When applied to...

Page 27: ...ype TOSHIBA specific socket TODX296 for RX and TX fiber usable plugs TOCP200Q TOCP200X CF 2071 9 6 Optic fiber interface modules for single mode fibers 9 6 1 LWLSM LWLSM or SH LWLSM PC104 Jack type 2 x ST BFOC bayonet for transmission and reception respectively Connect TX to RX and vice versa 10 Troubleshooting The card is accessible but no interrupts are generated Possible cause An insufficient n...

Page 28: ... 4W 5V 12V 3 3V or 5 0V automatic switchover 0 C to 55 C 0 C to 70 C Temperature range storage Dimensions w h d mm D PCIe D PCIu 20 C to 85 C 120 107 19 without connectors 120 107 19 without connectors D PCI104 Weight 90 96 11 without connectors according to PCI 104 specification max 250g incl packaging 11 1 1 ARCNET ARCNET Controller Compatibility Special feature Data rates COM20022 SMSC www smsc...

Page 29: ... DC Biasing Differential voltage output Cabling Connector up to 10 Mbit s 200 mV positive 115 ohm internal termination disabled by default 240 ohm 5 V 240 ohm 0 V biasing disabled by default min 3 0 V Twisted pair wire with 115 ohm line impedance recommended D sub DE9F socket galvanic insulation between D sub pins and shield 11 1 4 RS485AC Interfaces RS485AC RJ45 RS485AC BNC Data rate Line termina...

Page 30: ...eak output power Peak power wavelength Cabling Connector up to 2 5 Mbit s min 25 dBm max 9 2 dBm typ 14 dBm when coupled in 50 µm fiber four grades selectable very low low default medium high 820 nm Fiber types values in µm 50 125 or 62 5 125 or 100 140 LWLST 2 ST BFOC sockets LWLSMA 2 FSMA sockets 11 1 7 Optic Fiber Interface TOSLINK LWLTOS Data rate Optical input power Peak output power Peak pow...

Page 31: ... PCI104 as well as the SOHARD ARCNET interface modules meet the legal requirements for placement on the market in the European Economic Area CE marking The declarations of conformity may be requested under info sohard de 13 Contact Address SOHARD Embedded Systems GmbH Wuerzburger Str 197 90766 Fuerth Germany Tel 49 0 911 97341 522 566 Order management Technical support Fax 49 0 911 97341 510 eMail...

Page 32: ...ine dipulse BNC coaxial cable RG 62 SH ARC PCIu LWLSM 0 156 2 5 optical ST BFOC single mode fibers SH ARC PCIu LWLSMA 0 156 2 5 optical FSMA multi mode fibers SH ARC PCIu LWLST 0 156 2 5 optical ST BFOC multi mode fibers SH ARC PCIu LWLTOS 0 156 2 5 optical TODX296 TOSLINK multi mode fibers SH ARC PCIu R 0 156 10 RS 485 EIA 485 D sub twisted pair cable SH ARC PCIu RS485AC BNC 2 5 10 RS485AC BNC co...

Page 33: ...i mode fibers SH ARC PCIe LWLTOS 0 156 2 5 optical TODX296 TOSLINK multi mode fibers SH ARC PCIe R 0 156 10 RS 485 EIA 485 D sub twisted pair cable SH ARC PCIe RS485AC BNC 2 5 10 RS485AC BNC coaxial cable RG 62 SH ARC PCIe RS485AC RJ45 2 5 10 RS485AC RJ45 twisted pair cable SH ARC PCIe TWP 2 5 sine dipulse RJ45 twisted pair cable 16 3 SH ARC PCI104 card Order name Bit rate Mbit s Signal Socket Cab...

Page 34: ...lti mode fibers SH LWLTOS PC104 0 156 2 5 optical TODX296 TOSLINK multi mode fibers SH RS485 PC104 0 156 10 RS 485 EIA 485 D sub twisted pair cable SH RS485AC BNC PC104 2 5 10 RS485AC BNC coaxial cable RG 62 SH RS485AC RJ45 PC104 2 5 10 RS485AC RJ45 twisted pair cable SH TWP PC104 2 5 sine dipulse RJ45 twisted pair cable 17 Literature Reference Document 1 Datasheet COM20022B SMSC http www smsc com...