144
Netra X4200 M2 Server Service Manual • May 2007
Alarm Port
The alarm port on the alarm rear transition module uses a standard DB-15 connector.
In a telecommunications environment, use this port to connect to the central office
alarming system.
FIGURE D-6
shows the pin numbering of the alarm port, and
TABLE D-6
describes the pin signals.
Note –
The alarm port relay contacts are rated for 100 V 0.2 A maximum.
FIGURE D-6
Alarm Port Pin Numbering
Serial Attached SCSI Connector
The Serial Attached SCSI (SAS) connector pins and their corresponding descriptions
are shown in the figure and table in this section.
TABLE D-6
Alarm Connector Signals
Pin
Service
Pin
Service
1
NC
9
ALARM1_NC
2
NC
10
ALARM1_COM
3
NC
11
ALARM2_NO
4
NC
12
ALARM2_NC
5
ALARM0_NO
13
ALARM2_COM
6
ALARM0_NC
14
ALARM3_NO
7
ALARM0_COM
15
ALARM3_COM
8
ALARM1_NO
CHASSIS
FRAME GND
1
8
9
15
ALARM
Summary of Contents for Netra X4200 M2
Page 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Page 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Page 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Page 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Page 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Page 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Page 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Page 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Page 172: ...156 Netra X4200 M2 Server Service Manual May 2007...