Express5800/ 
A2040d/A2020d/A2010d/A1040d 
Configuration Guide

Introduction 

This document contains product and configuration information that will enable you to configure your system. The 
guide will ensure fast and proper configuration of your NEC Express5800 server. 

The available models depend on sales regions. For details, pleas

e contact your region’s sales representative. 

Mar. 2018 

Rev.3.0 

NEC Corporation

Summary of Contents for Express5800/A1040d

Page 1: ...uct and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server The available models depend on sales regions For details please contact your region s sales representative Mar 2018 Rev 3 0 NEC Corporation ...

Page 2: ...URATION 14 1 Base Models 14 1 1 A2040d 14 1 2 A2020d 15 1 3 A2010d 16 1 4 A1040d 17 1 5 COPT 18 2 CPU 19 3 Memory 21 3 1 Memory Riser Card 21 3 2 Memory Configuration 22 4 Internal Disk Drives 29 4 1 RAID Configuration 29 4 2 Internal Drive Configuration 31 5 Optical Drive 36 6 PCI Card 37 6 1 Network Interface Controller 37 6 2 External Storage Controller 41 7 Other Add in Components 44 7 1 Power...

Page 3: ...NCES 53 CPU 53 Memory 53 Internal Drive 59 Connection to RDX USB by Device Expansion Unit 62 Server Management 63 PCI Slot Available Slots and Installation Limitations 64 PCI Card Priority Order of Installation 74 RAS Feature Matrix per OS 78 Copyright Notice and Liability Disclaimer 82 REVISION HISTORY 83 ...

Page 4: ...298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 2319VA 2273W 2258VA 2213W 2319VA 2273W 2217VA 2173W 2115VA 2073W 2115VA 2073W 2319VA 2273W 2217VA 2173W 2370VA 2323W 2309VA 2263W 2370VA 2323W 2268VA 2223W 2166VA 2123W 2166VA 2123W 2370VA 2323W 2268VA 2223W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265...

Page 5: ... 60Hz 3Hz 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 2185VA 2141W 2136VA 2093W 2185VA 2141W 2103VA 2061W 2021VA 1981W 2021VA 1981W 2185VA 2141W 2103VA 2061W 2236VA 2191W 2187VA 2143W 2236VA 2191W 2154VA 2111W 2072VA 2031W 2072VA 2031W 2236VA 2191W 2154VA 2111W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W ...

Page 6: ...100V 200V 10 50 60Hz 3Hz 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 1381VA 1354W 1357VA 1330W 1381VA 1354W 1340VA 1314W 1300VA 1274W 1300VA 1274W 1381VA 1354W 1340VA 1314W 1432VA 1404W 1408VA 1380W 1432VA 1404W 1391VA 1364W 1351VA 1324W 1351VA 1324W 1432VA 1404W 1391VA 1364W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 92...

Page 7: ... 1265W 2311VA 2265W 2250VA 2205W 2311VA 2265W 2209VA 2165W 2107VA 2065W 2107VA 2065W 2311VA 2265W 2209VA 2165W 2362VA 2315W 2301VA 2255W 2362VA 2315W 2260VA 2215W 2158VA 2115W 2158VA 2115W 2362VA 2315W 2260VA 2215W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 2300VA 2254W 2239VA 2194W 2300VA 2254W 2198VA 2154W 2096VA 2054W 2096VA 2054W 230...

Page 8: ...N LED N NMI Button C PCI LED O RESET Button D MEM LED P UID LED E CPU LED Q UID Button F VLT TMP LED Voltage Temperature R SYSTEM POWER LED G CNFG LED Configuration S SYSTEM POWER Button H MISC LED T USB Connectors I NEXT LED U VGA Connector J NEXT Button V Optical Drive Bay K DISK Access LED W 2 5 inch Drive Bays L SYSTEM STATUS LED X Slide Tag A B P Q R E G I D F J KL M N BC H O S T U V W X ...

Page 9: ...D 1 K MGB 2 Maintenance LAN Connector 1 D PCI Slots Low Profile L MGB 2 Management LAN Connector 1 E UID Button M SUVCable Connector 2 F MGB 1 RESET Button N Power Supply Unit G MGB 2 RESET Button 1 O AC POWER LED H USB Connector P AC Inlet 1 Not applicable with A1040d 2 2x USB Connectors and 1x Serial Port and 1 x VGA Connector are available through SUV Cable attachement to the server 2m length A...

Page 10: ...NEC Express5800 A2040d A2020d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 10 Dimensions mm A2040d A2020d A2010d A1040d In case of using slide rail attachment with a cable arm The above illustrations includes inner rails ...

Page 11: ...C Express5800 A2040d A2020d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 11 Configuration Diagram A2040d Legend Standard components Minimum required components A2020d Legend Standard components Minimum required components ...

Page 12: ...ON GUIDE NEC Express5800 A2040d A2020d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 12 A2010d Legend Standard components Minimum required components A1040d Legend Standard components Minimum required components ...

Page 13: ... Slot 15 PCI Express 3 0 x8 lane x8 socket Slot 16 PCI Express 3 0 x8 lane x8 socket NOTE For all PCI slots Low Profile 167 6mm in length PCI slot performance x4 lane for Slot 8 and 9 x8 lane for the others Hot Plug supported Slot 2 to 9 8 slots not available with A1040d For A2040d Slot 1 to 9 are available in case of 2CPU configuration Slot 1 to 13 are available in case of 3CPU configuration and ...

Page 14: ...400 161F NOTE The base model must be ordered with processor kits memory riser cards memory kit power supply units Power cables should be ordered as well for each geo Front Bezel and Cable Arm are not attached need to be ordered separately if required Number of the available PCI Slots and Memory Riser Card depends on the number of CPUs Available PCI Slots and Maximum No of Memory Riser Card No of C...

Page 15: ...0 144F NEC Express5800 A2020d 10C E7 4820v4 2x Intel Xeon Processor E7 4820v4 2 00 GHz 10C 20T 25MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 145F NEC Express5800 A2020d 8C E7 4809v4 2x Intel Xeon Processor E7 4809v4 2 10 GHz 8C 16T 20MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 146F NEC Express5800 A2020d 10C E7 8891v4 2x Intel Xeon Processor E7 8891v4 2 80 GHz 10C 20T 6...

Page 16: ...S NE3400 154F NEC Express5800 A2010d 10C E7 4820v4 1x Intel Xeon Processor E7 4820v4 2 00 GHz 10C 20T 25MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 155F NEC Express5800 A2010d 8C E7 4809v4 1x Intel Xeon Processor E7 4809v4 2 10 GHz 8C 16T 20MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 156F NEC Express5800 A2010d 10C E7 8891v4 1x Intel Xeon Processor E7 8891v4 2 80 GHz 10...

Page 17: ...ser cards memory kit power supply units Power cables should be ordered as well for each geo Front Bezel and Cable Arm are not attached need to be ordered separately if required Number of the available PCI Slots and Memory Riser Card depends on the number of CPUs Available PCI Slots and Maximum No of Memory Riser Card No of CPU Max No of Memory Riser Available PCI Slots 1 2 3 4 5 6 7 8 9 10 11 12 1...

Page 18: ...cket license based software please enable CPU core at the CPU socket on which the software is operating Software license is required for the socket with at least one enabled CPU core Depending on the OS the server may need to be rebooted to enable CPU cores Remarks to use COPT under Linux environment When using Fibre Channel Controller 16Gbps NE3390 157A 158A need to enable enough number of CPU co...

Page 19: ...ar items NE3301 H022F Xeon E7 8867v4 Processor Kit 1x Intel Xeon Processor E7 8867v4 2 40 GHz 18C 36T 45MB NE3301 H023F Xeon E7 8855v4 Processor Kit 1x Intel Xeon Processor E7 8855v4 2 10 GHz 14C 28T 35MB NE3301 H024F Xeon E7 4820v4 Processor Kit 1x Intel Xeon Processor E7 4820v4 2 00 GHz 10C 20T 25MB NE3301 H025F Xeon E7 4809v4 Processor Kit 1x Intel Xeon Processor E7 4809v4 2 10 GHz 8C 16T 20MB ...

Page 20: ...nology to provide hardware CPU support for processor virtualization Security Execute Disable Technology to avoid the execution of malware utilizing buffer over flow error The maximum number of logical processors supported by OS See the table below for the maximum number of logical processors that you can actually use on your system Maximum Number of Logical Processors Supported by Operating System...

Page 21: ...nce section for Memory Riser Card installation priority order For A2040d including COPT model A2020d A2010d Product Name Description Part Number Memory Riser Card Module with 8x DIMM slots NE3302 H003 NOTE 1 or 2 MRs can be installed per CPU thus up to 8 MRs can be installed with 4CPU configuration A2020d Up to 8 MRs can be installed A2010d Up to 4 MRs can be installed Not pre installed At least o...

Page 22: ...ng and Memory Mirroring Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported Independent Mode only Memory Rank Sparing under Independent Mode Memory Mirroring under Independent Mode Summary In case of correctable errors switching to spare memory rank Redundant memory having the same data Available Memory 1 2 8GB RDIMM 1 2 16GB RDIMM...

Page 23: ...RDIMM 512GB 16GB RDIMM 1024GB 32GB RDIMM Data Correction ECC DDDC Notes RDIMM and LRDIMM cannot be mixed Need to order memory for sparing Need to order memory for mirroring 3 4 memory channels per Memory Riser Card 4 All DIMMs have the same capacity Customized Configuration Service at the Server Delivery Product Name Description Part Number Customized Service Distribution Mode for COPT NE3300 SV10...

Page 24: ...IMM DDR4 2133 PC4 2133 ECC NE3302 H042F Load Reduced DIMM LRDIMM 64GB MEM 2x32GB LRDIMM CTO 2x 32GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different from other regular items NE3302 H043F 128GB MEM 2x64GB LRDIMM CTO 2x 64GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different ...

Page 25: ...MM DDR4 2133 PC4 2133 ECC NE3302 H042F Load Reduced DIMM LRDIMM 64GB MEM 2x32GB LRDIMM CTO 2x 32GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different from other regular items NE3302 H043F 128GB MEM 2x64GB LRDIMM CTO 2x 64GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different f...

Page 26: ...r at least 1 set 4x DIMM RDIMM and LRDIMM cannot be mixed in a server 1 spare rank available with 8GB 16GB RDIMM 1 or 2 spare ranks available with 32GB RDIMM Logical Memory Capacity at Memory Rnak Sparing ex using the same capacity DIMMs No of DIMM Physical Memory Capacity 8GB RDIMM 16GB RDIMM 32GB RDIMM 1 Spare Rank 1 Spare Rank 1 Spare Rank 2 Spare Ranks 4 16GB 32GB 96GB 64GB 8 32GB 64GB 192GB 1...

Page 27: ... NE3302 H062F NOTE Not preinstalled Need to order at least 1 set 4x DIMM RDIMM and LRDIMM cannot be mixed in a server Memory Clock DDR4 Memory clock depends on CPU and Memory Configuration Please refer to below for the maximum clock Please refer to Memory of Reference section for the details too CPU Memory Configuration Mode Memory Type No of DIMMs per 1CPU Clock 1 2V Xeon E7 8890v4 E7 8880v4 E7 8...

Page 28: ...s Server 2012 R2 Datacenter 1 4TB 4TB Microsoft Windows Server 2016 Standard 1 Microsoft Windows Server 2016 Datacenter 1 24TB 4TB Red Hat Enterprise Linux 6 8 6 9 x86_64 12TB 2TB Red Hat Enterprise Linux 7 2 7 3 12TB 2TB VMware ESXi 6 0 update2 update3 2 6TB 4TB Vmware ESXi 6 5 6 5 update1 3 12TB 4TB Vmware ESXi 6 5 update1 3 12TB 4TB 1 The Maximum Memory Capacity in using Hyper V Windows Server ...

Page 29: ...o of Drive 4 Y NOTE Needs to order RAID Controller to configure internal drives For RAID Configuration same type of internal drives need to be ordered within one RAID group pack Multiple RAID group can be configured by one RAID Controller In case of RAID1 4 groups at maximum Different capacity rotation speed disk type of internal drives can be mixed among different RAID groups When configuring hot...

Page 30: ...A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 30 1x RAID Controller Configuration 2x RAID Controller Configuration 4 2 1 SAS HDD SSD 2GB Cache Flash 1GB Cache Flash 4 2 2 4 2 3 SAS HDD SSD 2GB Cache Flash SAS HDD SSD 1GB Cache Flash 4 2 4 SAS HDD SSD ...

Page 31: ...ixing these drives please refer to the section Internal Disk at References RAID 0 1 5 6 10 can be configured at BTO Configuration For RAID 50 60 need to configure after the delivery With 2 RAID Controller configuration the 2nd RAID Controller and 5th and more HDDs cannot be configured at BTO Configuration With 2 RAID Controller configuration RAID cannot be configured between internal drives under ...

Page 32: ...inch 12Gb s 10 000 rpm 512B sector NE3350 479M 600GB HDD 1x600 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 481M 900GB HDD 1x 900 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 1...

Page 33: ... inch 12Gb s 10 000 rpm 512B sector NE3350 479M 600GB HDD 1x600 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 481M 900GB HDD 1x 900 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch ...

Page 34: ...NE3350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 486M 600GB HDD 1x 600 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 518M SAS SSD eMLC 200GB SSD CTO 1x 200 GB SAS SSD eMLC 2 5 inch 12Gb s 512B s...

Page 35: ...NE3350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 486M 600GB HDD 1x 600 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 518M SAS SSD eMLC 200GB SSD CTO 1x 200 GB SAS SSD eMLC 2 5 inch 12Gb s 512B s...

Page 36: ...nternal Internal DVD ROM Drive Slim DVD ROM Drive SATA NOTE Supported OS Windows Server 2012R2 Red Hat Enterprise Linux and VMware NE3351 134M Internal DVD Super Multi Drive Slim DVD Super Multi drive SATA NOTE Supported OS Windows Server 2012R2 NE3351 135M NOTE Not pre installed Needs to order either Internal DVD ROM Drive or Internal DVD Super Multi Drive for server maintenance and or OS install...

Page 37: ... Broadcom BCM5719 PCIe 2 0 x4 Low Profile NOTE Network cables with RJ 45 plug covers cannot be used NE3304 152M 10GbE 10GBASE Adapter SFP 2ch Qlogic NetXtreme II BCM57810S PCIe 2 0 x8 Low Profile NOTE When connecting to the optical fibre cable NE3304 129 SFP Module 10G SR needs to be ordered per one port max 2 Connection with Twinax cable is available Please refer to the Users guide for the valida...

Page 38: ...ndancy is supported with Taming Bonding functions supported by OS See the table below for supported network interfaces operation mode and number of teams Windows Teaming Network Interface Operation Mode Configuration Number of Teams NE3304 151M 152M 1000BASE T Generic or static Teaming Dynamic teaming Switch independent 4 ports in one card 4 ports among multiple cards Up to 4 ports per one team Up...

Page 39: ... 10GBASE T 2 ports in one card 2 ports among multiple cards Up to 2 ports per one bonding Up to 8 teams NOTE Network interface for teaming should be all the same Concatct to our sales representative for other than Active backup Can mix 1000BASE bonding 10GBASE SR bonding and 10GBASE T bonding within one system ...

Page 40: ...r configuration See the table below for supported network interface and OS combinations Network Interface Operating System GbE NE3304 151M 152M Windows Server 2012 R2 VMware 10GbE 10GBASE SR NE3304 149 159 Windows Server 2012 R2 VMware 10GbE 10GBASE T NE3304 157 Windows Server 2012 R2 VMware RHEL Red Hat Enterprise Linux NOTE NIC Teaming Bonding features are not supported on iSCSI interfaces Redun...

Page 41: ...sion Unit 2U N8192 101 N8192 102 N8192 103 N8192 104 SAS Cable 2m for N8192 101 N8192 102 K410 322 02 SAS Cable 2m for N8192 103 N8192 104 K410 333 02 Disk Expansion Unit can be placed just above or just below the server BTO configuration at the server delivery does NOT include RAID configuration Please do RAID configuration by using utility setting By using Flash Backup Unit Write Back is availab...

Page 42: ...e and OS by iStorage series Please refer to the EXPRESSCLUSTER web site for cluster configuration Depending on the FibreChannel FC link speed the available cable type and or length may differ Please refer to the users guide for the Fibre Channel Controller As 2m cables are used to connect SAS Controller and Device Expansion Unit the following remarks should be noted when using Device Expansion Uni...

Page 43: ...d to connect SAS Controller and LTO rack mount type the following remarks should be noted when using the LTO rack mount type LTO 1U N8160 94 95 100 Cannot be mounted on top of the server with 0U from the server Can be mounter just below the server with 0U from the server If need to mount with 1 3U from the server on top or under the location o the SAS Controller should be adjusted Please contact t...

Page 44: ...3 4 Not available A2020d 1000W 2 3 4 Not available 800W 2 3 4 Not available A2010d 1000W 1 2 3 4 800W 1 2 3 4 A1040d 1000W 1 1 2 2 2 3 2 3 4 4 3 4 Not available 800W 1 2 2 3 4 3 4 3 4 Not available NOTE When selecting Power Supply Unit recommend to consider potential add on of the optional products in the future Redundancy can be selectable no redundancy N 1 and 2N N 1 When one Power Supply Unit f...

Page 45: ...standard NOTE 2 units are installed as standard no add on available Hot plug supported 7 3 Trusted Platform Module Kit Product Name Description Part Number Trusted Platform Module Kit TPM 1 2 compliant Module needed to use Windows BitLocker Drive Encryption feature Supported OS Windows Server 2012R2 NE3315 21 Trusted Platform Module Kit TPM 2 0 compliant Module needed to use Windows BitLocker Driv...

Page 46: ...l Flash Memory With this kit EXPRESSBUILDER can be started from POST NE3315 07 NOTE When this flash memory is ordered and shipped with the server the data in the EXPRESSBUILDER is copied into this kit When this flash memory is ordered and shipped separately the data must be copied from the EXPRESSBUILDER DVD to the flash memory after installing it in the server for use ...

Page 47: ...oard Optical mouse 1U height 4 pin USB B to 4 pin USB A cable 2 m PS 2 Y splitter cable 2m 15 pin mini D sub VGA cable 2 m BLACK N8143 105F 17inch LCD Console Drawer 1port 17 inch LCD US 103 keys Keyboard with 10 key Touch pad with 3 button 1U height 4 pin USB B to 4 pin USB A cable 1 8 m Two PS 2 cable 1 8 m 15 pin mini D sub VGA cable 1 8 m N8143 108F Keypad Keyboard Unit JP JP 108 keys Keyboard...

Page 48: ...i D sub 1 x 4 pin USB A K410 118 03 Switch Unit Connection Cable Set USB 5m 5 m 1 x 15 pin mini D sub 1 x 15 pin mini D sub 1 x 4 pin USB A K410 118 05 Cascading Switch Unit Connection Cable 1 8 m 1 8 m 1 x 15 pin mini D sub 1x 15 pin mini D Sub 2x PS 2 K410 119 1A NOTE Need Switch Unit Connection Cable for the number of servers up to 8 server There is one VGA connector on the front side of the se...

Page 49: ...20d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 49 8 3 Front Bezel A2040d A2020d A2010d Product Name Description Part Number Front Bezel A2040d A2020d A2010d NE3446 H001 A1040d Product Name Description Part Number Front Bezel A1040d NE3346 H001 ...

Page 50: ...s For calculation considering LAN UTP without shield is φ5mm in diameter at average 1x FC cable corresponds to 1x LAN cable 1x SAS cable corresponds to 2x LAN cables 1x SUV cable corresponds to 4x LAN cables and 1 x USB Cable corresponds to 1 x LAN cable Table for quick reference Model A2040d A2020d A2010d A1040d Cable Arm 70mm Cable Arm 110mm Cable Arm 70mm Cable Arm 110mm Max cable capacity by n...

Page 51: ...CONFIGURATION GUIDE NEC Express5800 A2040d A2020d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 51 ...

Page 52: ...ava JRE7 8 32bit version J2SE Runtime Environment for Windows terminal Java7u55 and above for Windows 8 1 Client OS Windows Windows Vista SP2 Windows 7 Windows 8 1 Windows 10 Windows Server 2008 Windows Server 2008 R2 SP1 Windows Server 2012 Windows Server 2012 R2 with IPv6 Windows 7 Windows 8 1 Windows 10 Windows Server 2012 Windows Server 2012 R2 Linux Red Hat Enterprise Linux version 6 Red Hat ...

Page 53: ...on the number of the installed CPU and the ordered Memory Riser Card Memory Riser Cards will be installed in the following priority order Need to install at least one Memory Riser Card of CPU Memory Riser Card Slot 1 2 3 4 5 6 7 8 2 1 3 2 4 3 1 4 2 5 3 6 4 1 5 2 6 3 7 4 8 2 COPT Supported Model Standard BTO Configuration Centralized Mode Depending on the number of the installed CPU and the ordered...

Page 54: ...rd Memory Riser Cards will be installed in the following priority order Need to install at least one Memory Riser Card of CPU Memory Riser Card Slot 1 2 3 4 5 6 7 8 2 1 3 2 4 5 7 6 8 1 3 A2010d Up to 4 Memory Riser cards are able to be installed Depending on the number of the ordered Memory Riser Card Memory Riser Card will be installed in the following priority order Need to install at least one ...

Page 55: ...TE Cannot mix RDIMM and LRDIMM in a server Lockstep Mode is a standard setting at the server delivery For DIMM installation priority order 1 to install larger DIMM first and 2 to install DIMMs to the sockets in the priority order shown in the figure below 2 2 Independent Mode Independent Mode provides more performance by having 4 memory channels operate independently This supports Error Detect Cor...

Page 56: ...tep Mode Mirroring between memory pair on CH0 and CH1 AND memory pair on CH2 and CH3 NOTE Cannot mix RDIMM and LRDIMM in a server When using Memory Mirroring the available memory capacity becomes half of physical capacity Lockstep Mode Memory Mirroring is a standard setting at the server delivery To use Independent Mode need to change the mode from BIOS set up menu Cannot use both Memory Mirroring...

Page 57: ...step Mode one or 2 memory rank out of 2 DIMMs in one memory channel is assigned as a spare per memory pair of lock step NOTE Cannot mix RDIMM and LRDIMM in a server When using Memory Rank Sparing the available memory capacity reduces by the capacity of spare memory rank Available Memory Capacity 1 2 of physical memory 8GB RDIMM 1 2 3 4 of physical memory 16GB RDIMM Lockstep Mode Memory Rank Sparin...

Page 58: ...OPT Supported Model Standard BTO Configuration Centralized Mode Memory will be installed to the first younger 2 Memory Riser Cards Follows the same rule afterwards 3 COPT Supported Model With Customized Service Distribution Mode for COPT NE3300 SV101 is ordered Decentralized Mode Memory will be installed equally among each Memory Riser Card 3 2 A2020d Memory will be installed equally to Memory Ris...

Page 59: ...r mixing HDDs with the same rotation speed is supported in the BTO configuration Mixing HDDs with different rotation speed and mixing HDD and SSD is NOT supported in the BTO configuration Cannot mix the different drives within a RAID group pack When defining hot spare disk under mixed drive configuration need to set Dedicated Hot Spare per RAID group Global Hot Spare is not available Please refer ...

Page 60: ...CONFIGURATION GUIDE NEC Express5800 A2040d A2020d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 60 ...

Page 61: ... if the number of drive is odd will set one spare drive NE3303 178 or NE3303 177 Q ty 2 4 2 3 4 2 4 Up to 4 drives 1 RAID 0 Q ty 1 2 RAID 1 Q ty 2 3 4 RAID 1 if the number of drive is odd will set one spare drive NOTE Up to 4 RAID group pack per server 2nd RAID Controller and 5th and later HDDs under it no RAID Configuration applied Need to order same capacity rotation speed drives in one group di...

Page 62: ...the top or bottom of the server In case of locating directly on top or bottom of the server within 0U all devices device 1 4 are available In case of locating within 1 3U space device 3 4 on the left hand side from the front right connecter 3 4 from the rear can be available Devices within 660mm in depth can be installed between the server and the Device Expansion Unit Device Expansion Unit N8141 ...

Page 63: ...on off dump Remote power capping BIOS BMC FW update Remote BIOS setup partial configuration only OS shutdown 1 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Scheduling without UPS ESMPRO SM required 1 Maintenance EXPRESSSCOPE Profile Key Backup restore BIOS BMC setup information Others Set automatic IP address v...

Page 64: ...o connect to internal disks Up to 2 Controllers same type can be installed Flash Backup Unit NE3303 H003 can be added 4 RAID Controller 1GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 External RAID Controller 2GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 SAS Controller 6Gb s SAS Card Perf PCI Express 2 0 x8 To connect external device units SAS Controller 12Gb s SAS Card Perf PCI Express 3 0 x8 Fibre...

Page 65: ...ard operates according to the specification of the slot PCI Slot 2 to 9 are hot plug supported 1 For configuring 4 cards please contact to our sales rep for the details Product Code NE3303 178 NE3303 177 NE3303 H004 NE3303 142 NE3303 184 SASController 12Gb s SAS Name Description RAIDController 2GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAIDController 1GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAIDCo...

Page 66: ... PCI Express 2 0 x4 For LAN connection LAN cables with RJ 45 plug covers cannot be used 16 To connect to internal disks Up to 2 Controllers same type can be installed Flash Backup Unit NE3303 H003 can be added 4 RAID Controller 1GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 External RAID Controller 2GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 SAS Controller 6Gb s SAS Card Perf PCI Express 2 0 x8 T...

Page 67: ...etails about each card Card Perf Means the maximum operating performance of the card If the PCI slot specification is lower than the operation performance of the cards the card operates according to the specification of the slot Product Code NE3303 178 NE3303 177 NE3303 H004 NE3303 142 NE3303 184 SASController 12Gb s SAS Name Description RAIDController 2GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAI...

Page 68: ...Xeon E7 8867v4 Xeon E7 8855v4 Xeon E7 8891v4 Xeon E7 4820v4 Xeon E7 4809v4 Xeon E7 8893v4 15 cores or more 11 cores or more 7 cores or more 16 16 16 16 16 2 Max number of slots depends on the number of CPU Max slot 2CPU 9slots 3CPU 13slots 4CPU 16slots 1 By using PCI card spending less I O space the number of Cores needed to beenabled becomes less Max of slots 1 The followins is the guide line of ...

Page 69: ...ts Matrix general Fibre Channel Controller 2port 8Gbps Optical SAS Controller 6Gb s SAS SAS Controller 12Gb s SAS 1000BASE T Adapter 2port Same as Available Slots Matrix general Max 8 ports in total per CPU 1000BASE T Adapter 4port 10GBASE Adapter SFP 2ch 10GBASE Tadapter 2port Fibre Channel Controller 1port 16Gbps Optical Max 2 ports in total per CPU Fibre Channel Controller 2port 16Gbps Optical ...

Page 70: ...I card spending less I O space the number of Cores needed to beenabled becomes less Max of slots 1 1 Max number of slots depends on the number of CPU Max slot 1CPU 4slots 2CPU 9slots 3CPU 13slots 4CPU 16slots The followins is the guide line of the number of cores which should be enabled at A2040d COPT A2040d COPT of CPU of Cores needed to be enabled 1 Fibre Channel Controller 1port 8Gbps Optical S...

Page 71: ...nnel Controller 2port 8Gbps Optical SAS Controller 6Gb s SAS 1000BASE T Adapter 2port Same as Available Slots Matrix general Max 8 ports in total per CPU Max 4 ports in total per CPU 1000BASE T Adapter 4port 10GBASE Adapter SFP 2ch 10GBASE Tadapter 2port Fibre Channel Controller 1port 16Gbps Optical Max 2 ports in total per CPU Max 1 port in total per CPU Max of slots 1 A2010d Name Description RAI...

Page 72: ...tion to the above please also follow Available Slots Matrix general and Installation Limitations due to I O Space 1 Max number of slots depends on the number of CPU Max slot 1CPU 4slots 2CPU 9slots 3CPU 13slots 4CPU 16slots 2 By using PCI card spending less I O space the max number will be increased 3 NE3304 142 SAS Controller 6Gb s 12Gb s not supported for VMware environment 4 For Lan card and FC...

Page 73: ...n Limitations due to I O Space 1 Max number of slots depends on the number of CPU Max slot 1CPU 4slots 2CPU 9slots 3CPU 13slots 4CPU 16slots 2 By using PCI card spending less I O space the max number will be increased 3 NE3304 142 and NE3303 184 SAS Controller 6Gb s 12Gb s not supported for VMware environment 4 for Lan card and FC Contoller please follow Limitation of VMware ESXi6 0 Max of slots 1...

Page 74: ...ity 1 7 can be installed Up to 7 cards for the cards except 1000BASE T Adapter 2ch 4ch and SAS Controller can be installed In case of having 13 slots available Up to 12 cards for the cards with Priority 1 7 can be installed Up to 11 cards for the cards except 1000BASE T Adapter 2ch 4ch and SAS Controller can be installed Up to 9 cards for 10G BASE Adapter SFP and External RAID Controller in total ...

Page 75: ...57 10GBASE T Adapter 2ch Can install to any slot other than Slot 1 8 and 9 8 NE3304 152M 1000BASE T Adapter 4 port Can install to any slot other than Slot 1 9 NE3303 184 SAS Controller 12Gbps Can install to any slot other than Slot 1 NE3303 142 SAS Controller 6Gbps Priority of PCI Slots PCI Slot Number of Available Slots per CPU configuration 4 9 13 16 1 Y Y Y Y 9 N Y Y Y 12 N N Y Y 16 N N N Y 5 Y...

Page 76: ...BASE T Adapters in total can be installed In case of having 9 slots available Up to 7 cards for the cards with Priority 1 5 can be installed In case of having 13 slots available Up to 11 cards for the cards with Priority 1 5 can be installed Up to 9 10G BASE Adapters SFP and External RAID Controllers in total can be installed In case of having 16 slots available Up to 14 cards for the cards with P...

Page 77: ...o any slot NE3304 151M 1000BASE T Adapter 2 port Can install to any slot other than Slot 1 NE3304 152M 1000BASE T Adapter 4 port Priority of PCI Slots PCI Slot Number of Available Slots per CPU configuration 4 9 13 16 1 Y Y Y Y 12 N N Y Y 7 N Y Y Y 16 N N N Y 4 Y Y Y Y 10 N N Y Y 2 N Y Y Y 14 N N N Y 3 Y Y Y Y 11 N N Y Y 6 N Y Y Y 15 N N N Y 5 Y Y Y Y 13 N N Y Y 9 N Y Y Y 8 N Y Y Y NOTE The 2nd RA...

Page 78: ... PFA RHEL6 x64 RHEL7 Y Y Y Y 1 WS2012R2 WS2016 Y Y Y Y 2 ESXi6 0 ESXi6 5 Y Y Y Y Dynamic CPU Core De allocation RHEL6 x64 RHEL7 Y Y Y N 1 WS2012R2 WS2016 N N N N ESXi6 0 ESXi6 5 N N N N Dynamic Memory Page De allocation Memory Page Offline RHEL6 x64 RHEL7 Y Y Y N 1 WS2012R2 WS2016 Y Y Y Y 2 ESXi6 0 ESXi6 5 Y Y Y Y PCIe Hot Add PCIe Hot Remove RHEL6 x64 RHEL7 Y Y Y N WS2012R2 WS2016 Y Y Y N ESXi6 0...

Page 79: ...eboot Required COPT Model RHEL6 x64 RHEL7 2 Y COPT N N N 4 RHEL7 3 N N N N WS2012R2 WS2016 Y COPT N N N 5 ESXi6 0 ESXi6 5 Y COPT N N N Dynamic COPT Core Enabling COPT Model RHEL6 x64 RHEL7 Y COPT N N N 1 WS2012R2 WS2016 N N N N ESXi6 0 ESXi6 5 N N N N Dynamic COPT CORE Sparing COPT Model RHEL6 x64 RHEL7 Y COPT N N N 1 WS2012R2 WS2016 N N N N ESXi6 0 ESXi6 5 N N N N ...

Page 80: ... 5 N N N N Reliable Memory RHEL6 x64 RHEL7 N N N N WS2012R2 WS2016 N N N N ESXi6 0 N N N N ESXi6 5 Y Y Y Y MCA Recovery RHEL6 x64 RHEL7 Y Y Y Y WS2012R2 WS2016 Y Y Y Y ESXi6 0 ESXi6 5 Y Y Y Y Enhanced MCA Recovery Gen 2 BIOS MCA Recovery on Gen2 MCA added by E7v3 gen RHEL6 x64 RHEL7 Y Y Y N WS2012R2 WS2016 Y Y Y N ESXi6 0 ESXi6 5 Y Y Y N PCIe Live Error Recovery RHEL6 x64 RHEL7 Y Y Y Y 1 WS2012R2 ...

Page 81: ... specific kernel version 2 Please install spport kit UPDATE module in the EXPRESSBUILDER With Windows Seamless Install the necessary modules are automatically installed 3 Please install the necessary module according to the documents Mission Critical I O Failover User s Guide 4 As an option if you install the necessary module acccording to the documents Machine Check Monitoring Service User s Guid...

Page 82: ...tries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for...

Page 83: ...E NEC Express5800 A2040d A2020d A2010d A1040d NEC Corporation Rev 2 0 Oct 2017 83 Revision History Revision Date Description Rev 1 0 September 2016 Initial Release Rev 2 0 October 2017 Updates Rev 3 0 March 2018 Updates ...

Reviews: