30
Netra X4200 M2 Server Service Manual • May 2007
■
NET MGT
■
USB 1
■
USB 0
■
NET 0
■
NET 1
■
NET 2
■
NET 3
■
Power supply 0
■
Power supply 1
Caution –
Before unplugging the AC or DC power cords from the server or
handling internal components, attach an electrostatic discharge (ESD) wrist strap to
the button-snap grounding post inside the chassis just behind the mass storage
assembly (see
FIGURE 3-10
for the location). The system’s printed circuit boards and
hard disk drives contain components that are extremely sensitive to static electricity.
3. Disconnect both power cords from the server’s power supplies.
4. Turn off all peripheral devices connected to the system server.
5. Label any peripheral cables and/or telecommunication lines that must be
disconnected in order to remove and replace a specific component.
6. Remove the server from the rack. See
“Removing the Server From the Rack” on
page 30
Removing the Server From the Rack
Caution –
The server weighs approximately 40 lb (18 kg). Two people are required
to dismount and carry the chassis.
1. Disconnect all the cables and power cords from the server.
2. From the front of the server, release the slide rail latches on each side.
Pinch the green latches as shown in
FIGURE 3-3
.
Summary of Contents for Netra X4200 M2
Page 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Page 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Page 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Page 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Page 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Page 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Page 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Page 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Page 172: ...156 Netra X4200 M2 Server Service Manual May 2007...