98
Netra X4200 M2 Server Service Manual • May 2007
FIGURE 3-72
Installing a Power Supply Into the Chassis
4. Reconnect the power cord to the power supply.
5. Verify that the amber LED on the replaced power supply and the Service
Required LEDs are not lit.
Replacing the Power Distribution Board
Removing the Power Distribution Board
1. Prepare the server for power board removal. See:
■
“Powering Off the Server” on page 28
■
“Disconnecting Cables From the Server” on page 29
■
“Removing the Server From the Rack” on page 30
■
“Performing Antistatic Measures” on page 31
■
“Removing the Top Cover” on page 33
■
“Opening the Front Bezel” on page 33
■
“Removing the PCI Tray and PCI-E Ribbon Cables” on page 34