134
Netra X4200 M2 Server Service Manual • May 2007
TABLE C-1
lists and describes the front and rear panel LEDs.
TABLE C-1
Front and Rear Panel LEDs
LED
Location
Color
Description
Locator LED
and button
front upper
left and rear
center
white
Enables you to identify a particular server. The LED is activated
using one of the following methods:
• Issuing the
setlocator on
or
off
command.
• Pressing the button to toggle the indicator on or off.
This LED provides the following indications:
• Off – Normal operating state.
• Fast blink – The server received a signal as a result of one of the
preceding methods.
Fault LED
front upper
left and rear
center
amber
If on, indicates that service is required. The ALOM
showfaults
command provides details about any faults that cause this indicator
to be lit.
Activity LED
front upper
left
green
• On – Drives are receiving power. Solidly lit if drive is idle.
• Flashing – Drives are processing a command.
• Off – Power is off.
Power button
front upper
left
Turns the host system on and off. This button is recessed to prevent
accidental server power-off. Use the tip of a pen to operate this
button.
Alarm:Critical
LED
front left
red
Indicates a critical alarm. Refer to the server administration guide
for a description of alarm states.
Alarm:Major
LED
front left
red
Indicates a major alarm.
Alarm:Minor
LED
front left
amber
Indicates a minor alarm.
Alarm :User
LED
front left
amber
Indicates a user alarm.
Power OK LED
rear center
green
The LED provides the following indications:
• Off – The system is unavailable. Either it has no power or ALOM
is not running.
• Steady on – Indicates that the system is powered on and is
running it its normal operating state.
• Standby blink – Indicates that the service processor is running
while the system is running at a minimum level in Standby
mode, and is ready to be returned to its normal operating state.
• Slow blink – Indicates that a normal transitory activity is taking
place. It might mean that the system diagnostics are running, or
that the system is booting.
Summary of Contents for Netra X4200 M2
Page 10: ...x Netra X4200 M2 Server Service Manual May 2007...
Page 14: ...xiv Netra X4200 M2 Server Service Manual May 2007...
Page 24: ...10 Netra X4200 M2 Server Service Manual May 2007...
Page 46: ...32 Netra X4200 M2 Server Service Manual May 2007 Sun ESD mat part number 250 1088...
Page 133: ...Chapter 3 Maintaining the Netra X4200 M2 Server 119...
Page 134: ...120 Netra X4200 M2 Server Service Manual May 2007...
Page 146: ...130 Netra X4200 M2 Server Service Manual May 2007...
Page 154: ...138 Netra X4200 M2 Server Service Manual May 2007...
Page 172: ...156 Netra X4200 M2 Server Service Manual May 2007...