331
Setup Data
5
Setup2 Editor
Carriage speed
5.5.5 Carriage speed
Different carriage speeds can be entered for different knitting situations. The
indirect carriage speed only becomes effective when it is slower than the
normal speed.
Carriage speed Setup2
Further information:
Explanation
Value range (meters/
second)
MSEC
Speed
(normal speed)
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
MSEC0
Speed for empty rows (S0)
Minimum value: 0.05
Maximum value: 1.40
Step width: 0.05
MSEC1
Speed for transfer rows
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
MSECI
Speed with Intarsia Yarn Carrier
(CMS ADF-3: Specification is not
taken into account)
Minimum value: 0.05
Maximum value: 1.00
(CMS-C: 0.7)
Step width: 0.05
MSECC
Speed outside the needle bed when
the yarn carrier is brought in the
clamp or taken out of the clamp.
Minimum value: 0.05
Maximum value: 0.50
Step width: 0.05
MSECK
Carriage speed for small knots over m
rows, standard: 1 row
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
MSEC2-20
Speed for knitting rows
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
Comment
Comment
ASCII Characters
Summary of Contents for CMS 502 HP+
Page 12: ...12 ...
Page 18: ...18 1 About this document Warnings in the documentation ...
Page 72: ...72 2 Description of knitting machine Display and operating elements ...
Page 128: ...128 3 Producing with the knitting machine Starting the machine after a fault ...
Page 302: ...302 4 Adjusting knitting machine Defining user profile ...
Page 522: ...522 9 Yarns and stitch tension Conversion table ...
Page 548: ...548 11 Machine Management Tools Send email directly from the machine ...
Page 562: ...Key word directory 562 ...