Repairing the knitting machine
7
Needle selection displacement
Reset reference values of impulse sensor, carry out carriage reference run
7.6.3 Reset reference values of impulse sensor, carry out
carriage reference run
Before determining the new values you have to delete the "old" values of the
impulse sensors.
Keys for deleting the reference values
Keys for deleting the reference values
1. Call up the "Service" menu from the "Main menu".
2. Call up "Basic Settings" menu.
3. Call up the "Machine parameters" window.
4. Call up "Additional function keys".
5. Call up the "Machine parameters 2" window.
6. Select all impulse sensors (activate control box). On a tandem machine
there are four impulse sensors.
7. Confirm input tapping on the (1) key.
8. You will be asked whether the values are to be deleted. Confirm this
message with "OK".
The values are deleted.
9. Carry out carriage reference run.
Key
Function
Call up the "Service" menu
Call up the "Basic settings" menu
Call up "Machine parameters" window
Call up "Additional function keys"
Call up "Machine parameters 2" window
Summary of Contents for CMS 502 HP+
Page 12: ...12 ...
Page 18: ...18 1 About this document Warnings in the documentation ...
Page 72: ...72 2 Description of knitting machine Display and operating elements ...
Page 128: ...128 3 Producing with the knitting machine Starting the machine after a fault ...
Page 302: ...302 4 Adjusting knitting machine Defining user profile ...
Page 522: ...522 9 Yarns and stitch tension Conversion table ...
Page 548: ...548 11 Machine Management Tools Send email directly from the machine ...
Page 562: ...Key word directory 562 ...