The Operator Station
5-1
605C Frequency Inverter
5
T
HE
O
PERATOR
S
TATION
Connecting the Operator Station
The Operator Station is a
plug-in MMI (Man-Machine
Interface) option that allows
full use of the Inverter’s
features.
It provides local control of the
Inverter, monitoring, and
complete access for
application programming.
Insert the Operator Station
into the front of the Inverter
(replacing the blank cover and
plugging into the RS232
programming port); or mount
it up to 3 metres away using
the optional panel mounting
kit with connecting lead. Refer
to Chapter 3: “Installing the
Inverter - Fitting the Remote
6051 Operator Station.
Two Operator Stations (or
one and a PC running a
suitable programming software) can be used simultaneously, each reflecting the others settings.
Welcome Screen
On power-up, a default Welcome screen is displayed for several seconds showing the product
description; power rating, voltage and software version of the Inverter.
After a few seconds the display changes to SETPOINT (REMOTE) by default.
Customising the Operator Station
This chapter contains information on how to customise the Operator Station to your application.
Below are some of the ways in which you can make the Operator Station work effectively for
you.
Consider the following features:
•
The Welcome screen can be customised so that it displays the process name, for example.
•
Create two custom screens for the user, using units and names relevant to the process.
•
Choose which parameters you need to see in the OPERATOR menu.
•
Set a password for the Operator Station to make all parameters “read-only”
•
Enable/disable the keys on the Operator Station as required, i.e., JOG, DIR etc.
•
Select the correct viewing level to reduce the menu size for easy operation.
HINT:
Customise the action of the Operator Station to create an effective working tool. Spend
time setting up the OPERATOR menu, as this is the list of parameters most used in the
operation of your Inverter. Refer to “Special Menu Features”, page 5-8.
Figure 5-1 Operator Station displaying Welcome Screen
EUROTHERM
DRIVES
E
M
PROG
L
R
Programming
Keys
Local
Control
Keys
JOG
1
DC 4Q 15A
DC D I V
R
E
I I T
G AL
D
OK
SEQ
REF
1
5.5kW 400V 5.x
AC
D I V
R
E
OTOR
M
Summary of Contents for 605C
Page 16: ...1 4 Getting Started 605C Frequency Inverter ...
Page 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Page 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Page 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Page 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Page 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Page 212: ...13 6 Application Notes 605C Frequency Inverter ...
Page 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Page 236: ......