Programming Your Application
6-73
605C Frequency Inverter
VALUE FUNCTION
The value function blocks can be configured to perform one of a number of functions upon a
fixed number of inputs.
MMI Menu Map
1
SETUP PARAMETERS
2
FUNCTION BLOCKS
3
MISCELLANEOUS
4
VALUE FUNCTIONS
5
VALUE FUNC 1
5
VALUE FUNC 2
5
VALUE FUNC 3
5
VALUE FUNC 4
5
VALUE FUNC 5
5
VALUE FUNC 6
5
VALUE FUNC 7
5
VALUE FUNC 8
5
VALUE FUNC 9
5
VALUE FUNC 10
INPUT A
INPUT B
INPUT C
TYPE
OUTPUT
VALUE FUNC 1
OUTPUT [133]
–
0.00 %
0.00 %
–
[130] INPUT A
–
0.00 %
–
[131] INPUT B
–
0.00 %
–
[132] INPUT C
–
IF(C) -A
–
[134] TYPE
–
VALUE FUNC 3
OUTPUT [143]
–
0.00 %
0.00 %
–
[140] INPUT A
–
0.00 %
–
[141] INPUT B
–
0.00 %
–
[142] INPUT C
–
IF(C) -A
–
[144] TYPE
–
VALUE FUNC 5
OUTPUT [153]
–
0.00 %
0.00 % – [150] INPUT A
–
0.00 %
–
[151] INPUT B
–
0.00 %
–
[152] INPUT C
–
IF(C) -A
–
[154] TYPE
–
VALUE FUNC 7
OUTPUT [163]
–
0.00 %
0.00 % – [160] INPUT A
–
0.00 %
–
[161] INPUT B
–
0.00 %
–
[162] INPUT C
–
IF(C) -A
–
[164] TYPE
–
VALUE FUNC 9
OUTPUT [173]
–
0.00 %
0.00 % – [170] INPUT A
–
0.00 %
–
[171] INPUT B
–
0.00 %
–
[172] INPUT C
–
IF(C) -A
–
[174] TYPE
–
VALUE FUNC 2
OUTPUT [138]
–
0.00 %
0.00 % – [135]
INPUT A
–
0.00 %
–
[136]
INPUT B
–
0.00 %
–
[137]
INPUT C
–
IF(C) -A
–
[139]
TYPE
–
VALUE FUNC 4
OUTPUT [148]
–
0.00 %
0.00 % – [145]
INPUT A
–
0.00 %
–
[146]
INPUT B
–
0.00 %
–
[147]
INPUT C
–
IF(C) -A
–
[149]
TYPE
–
VALUE FUNC 6
OUTPUT [158]
–
0.00 %
0.00 % – [155]
INPUT A
–
0.00 %
–
[156]
INPUT B
–
0.00 %
–
[157]
INPUT C
–
IF(C) -A
–
[159]
TYPE
–
VALUE FUNC 8
OUTPUT [168]
–
0.00 %
0.00 % – [165]
INPUT A
–
0.00 %
–
[166]
INPUT B
–
0.00 %
–
[167]
INPUT C
–
IF(C) -A
–
[169]
TYPE
–
VALUE FUNC 10
OUTPUT [178]
–
0.00 %
0.00 % – [175]
INPUT A
–
0.00 %
–
[176]
INPUT B
–
0.00 %
–
[177]
INPUT C
–
IF(C) -A
–
[179]
TYPE
–
If inputs and outputs are time values, divide the time in seconds by a factor of ten, i.e.
11.3 seconds = 1.13%.
Conversely, outputs are multiplied by a factor of ten to obtain their value in seconds.
Boolean inputs or outputs are FALSE if zero, and TRUE if non-zero.
Summary of Contents for 605C
Page 16: ...1 4 Getting Started 605C Frequency Inverter ...
Page 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Page 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Page 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Page 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Page 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Page 212: ...13 6 Application Notes 605C Frequency Inverter ...
Page 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Page 236: ......