Programming Your Application
6-77
605C Frequency Inverter
Operation
Description
TIMER
Times the period elapsed from when INPUT A is set TRUE and held TRUE,
to when INPUT B becomes TRUE.
OUTPUT is the duration of the timer, starting from zero. If INPUT B is
TRUE, the value for OUTPUT is held until INPUT B is released. If on
release INPUT A is still TRUE, the timer will continue from the held value.
Setting INPUT A and INPUT B to FALSE resets the timer.
INPUT C is not used.
MINIMUM
PULSE
Creates an output pulse of adjustable minimum time when INPUT A is
TRUE. (INPUT A is assumed to be a sequence of TRUE pulses and FALSE
off periods.)
INPUT B sets the length of the minimum pulse required. INPUT C inverts
the output when TRUE. The duration of the pulse is
at least
the period set by
INPUT B.
input A
input B
output
input A
output
input C FALSE
input C TRUE
Duration (input B)
t
input B
Summary of Contents for 605C
Page 16: ...1 4 Getting Started 605C Frequency Inverter ...
Page 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Page 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Page 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Page 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Page 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Page 212: ...13 6 Application Notes 605C Frequency Inverter ...
Page 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Page 236: ......