Application Macros
15-
19
605C Frequency Inverter
AUTOTUNE
ACTIVE
[604]
–
FALSE
FALSE
–
[603] ENABLE
–
CALC NO LOAD I
–
[689] MODE
–
CURRENT LIMIT
LIMITING [370]
–
FALSE
150.00% – [365] MOTOR I LIMIT
–
-150.00%
–
[623] REGEN I LIMIT
–
CURRENT
–
[366] FEEDBACK SOURCE
–
TRUE
–
[686] REGEN LIM ENABLE
–
DYNAMIC BRAKING
DC LINK VOLTS
[ 75]
–
0.0V
BRAKING
[ 81]
–
FALSE
TRUE – [ 80] ENABLE
–
100 Ohm
–
[ 77] BRAKE RESISTANCE
–
0.1kW
–
[ 78] BRAKE POWER
–
25
–
[ 79] 1 SEC OVER RATING
–
FLUXING
LINEAR LAW – [104] V/F SHAPE
–
100.00%
–
[105] V/F SCALE
–
* 50.0Hz
–
[106] BASE FREQUENCY
–
120Hz
–
[113] LIMIT FREQUENCY
–
0.00%
–
[107] FIXED BOOST
–
0.00%
–
[108] AUTO BOOST
–
FLYCATCHING
ACTIVE [576]
–
FALSE
SETPOINT
[ 28]
–
0.00%
FALSE
–
[570] ENABLE
–
ALWAYS
–
[571] START MODE
–
BIDIRECTIONAL
–
[572] SEARCH MODE
–
**9.00%
–
[573] SEARCH VOLTS
–
**40.00%
–
[ 32] SEARCH BOOST
–
**10.0s
–
[574] SEARCH TIME
–
5.0Hz
–
[575] MIN SEARCH SPEED
–
3.0s
–
[709] REFLUX TIME
–
SLEW RATE LIMIT
TRUE – [ 60] ENABLE
–
500.0Hz/s
–
[ 62] ACCEL LIMIT
–
500.0Hz/s
–
[ 61] DECEL LIMIT
–
STABILISATION
TRUE – [ 82] ENABLE
–
UNDERLAP COMP
TRUE – [600] ENABLE
–
VECTOR FLUXING
SUPPLY VOLTAGE
[596]
–
400.0V **
FALSE – [118] ENABLE
–
** STAR
–
[124] MOTOR CONNECTION
–
** 4.95 Ohm
–
[119] STATOR RES
–
** 52.5mH
–
[120] LEAKAGE INDUC
–
** 472.6mH
–
[121] MUTUAL INDUC
–
VOLTAGE CONTROL
NONE
[595]
VOLTAGE MODE
–
** 400.0V
–
[122]
MOTOR VOLTS
–
100.00%
–
[112]
BASE VOLTS
–
BRAKE CONTROL
RELEASE [587]
–
FALSE
HOLD [590]
–
FALSE
50.00% – [584] ON LOAD
–
5.0Hz
–
[585] ON FREQUENCY
–
3.0Hz
–
[586] OFF FREQUENCY
–
0.00s
–
[588] ON HOLD TIME
–
0.00s
–
[589] OFF HOLD TIME
–
MINIMUM SPEED
OUTPUT [335]
–
0.00%
0.00% – [336] INPUT
–
-100.00%
–
[337] MINIMUM
–
PROP. W/MIN.
–
[338] MODE
–
RAISE/LOWER
OUTPUT [325]
–
0.00%
FALSE
–
[327] RAISE INPUT
–
FALSE
–
[328] LOWER INPUT
–
10.0s
–
[326] RAMP RATE
–
100.00%
–
[330] MAX VALUE
–
-100.00%
–
[329] MIN VALUE
–
0.00%
–
[331] RESET VALUE
–
FALSE
–
[332] RESET
–
SKIP FREQUENCIES
OUTPUT [346]
–
0.0%
OUTPUT H z [363]
–
0.0Hz
INPUT H z [362]
–
0.0Hz
0.00% – [340] INPUT
–
0.0Hz
–
[341] BAND1
–
0.0Hz
–
[342] FREQUENCY 1
–
0.0Hz
–
[680] BAND 2
–
0.0Hz
–
[343] FREQUENCY 2
–
0.0Hz
–
[681] BAND 3
–
0.0Hz
–
[344] FREQUENCY 3
–
0.0Hz
–
[682] BAND4
–
0.0Hz
–
[345] FREQUENCY 4
–
LOCAL CONTROL
REMOTE SEQ
[297]
–
TRUE
REMOTE REF
[257]
–
TRUE
LOCAL/REMOTE
–
[298] SEQ MODES
–
LOCAL/REMOTE
–
[265] REF MODES
–
REMOTE
–
[299] POWER UP MODE
–
FALSE
–
[281] SEQ DIRECTION
–
COMMS CONTROL
COMMS SEQ [295]
–
FALSE
COMMS REF [270]
–
FALSE
COMMS STATUS [272]
–
0000
COMMS COMMAND
[273]
–
0000
FALSE – [300] REMOTE COMMS SEL
–
TERMINALS/COMMS
–
[307] REMOTE SEQ MODES
–
TERMINALS/COMMS
–
[308] REMOTE REF MODES
–
0.0s
–
[309] COMMS TIMEOUT
–
SYSTEM PORT (P3)
0 – [102] GROUP ID (GID)
–
0
–
[103] UNIT ID (UID)
–
CUSTOM SCREEN 1
0 – [ 74] TAG NO
–
–
[324] NAME
–
–
[323] UNITS
–
xxxxx.
–
[334] DECIMAL PLACE
–
A/B * X + C
–
[125] FORMULA
–
100
–
[321] COEFFICIENT A
–
100
–
[ 44] COEFFICIENT B
–
0
–
[322] COEFFICIENT C
–
30000
–
[101] HIGH LIMIT
–
-30000
–
[ 53] LOW LIMIT
–
CUSTOM SCREEN 2
0 – [371] TAG NO
–
–
[378] NAME
–
–
[377] UNITS
–
xxxxx.
–
[379] DECIMAL PLACE
–
A/B * X + C
–
[676] FORMULA
–
100
–
[375] COEFFICIENT A
–
100
–
[673] COEFFICIENT B
–
0
–
[376] COEFFICIENT C
–
30000
–
[674] HIGH LIMIT
–
-30000
–
[675] LOW LIMIT
–
OPERATOR MENU
1 – [93]
STARTUP SCREEN
–
255
–
[626] OPERATOR MENU 2
–
591
–
[627] OPERATOR MENU 3
–
67
–
[628] OPERATOR MENU 4
–
72
–
[629] OPERATOR MENU 5
–
75
–
[630] OPERATOR MENU 6
–
370
–
[631] OPERATOR MENU 7
–
0
–
[632] OPERATOR MENU 8
–
0
–
[633] OPERATOR MENU 9
–
0
–
[634] OPERATOR MENU 10
–
0
–
[635] OPERATOR MENU 11
–
0
–
[636] OPERATOR MENU 12
–
0
–
[637] OPERATOR MENU 13
–
0
–
[638] OPERATOR MENU 14
–
0
–
[639] OPERATOR MENU 15
–
OP STATION
OP DATABASE [115]
–
FALSE
OP VERSION [230]
–
0000
BASIC – [ 3]
VIEW LEVEL
–
* ENGLISH
–
[ 1]
LANGUAGE
–
00F0
–
[127] ENABLED KEYS
–
FALSE
–
[116] AUTO BACKUP
–
* AC MOTOR DRIVE
–
[339] CONFIGURATION ID
–
PASSWORD
ENTER PASSWORD
[ 7]
–
0000
CHANGE PASSWORD
[ 8]
–
0000
FALSE
–
[361] PROTECT LOCAL SP
–
FALSE
–
[364] PROTECT OP MENU
–
MOTOR CONTROL
SETPOINT FUNCS
SERIAL LINKS
SEQ & REF
MENUS
PATTERN GEN
DRIVE FREQUENCY
[591]
–
0.0Hz
VOLTS [592]
–
0.0V
BOOST [593]
–
0.0V
TRUE – [ 98] RANDOM PATTERN
–
3kHz
–
[ 99] FREQ SELECT
–
**2.0s
–
[100] DEFLUX DELAY
–
CURRENT FEEDBACK
MOTOR CURRENT
[ 66]
–
0.00 %
MOTOR CURRENT
[ 67]
–
0.0 A
I MAGNETISING
[ 68]
–
0.00 %
I MAGNETISING
[ 69]
–
0.0 A
I TORQUE
[ 70]
–
0.00 %
I TORQUE
[ 71]
–
0.0 A
LOAD
[ 72]
–
0.00 %
FIELD
[ 73]
–
0.00 %
**2.0 A – [ 64]
FULL LOAD CALIB
–
**1.4 A
–
[ 65]
NO LOAD CALIB
–
**0.70
–
[242] POWER FACTOR
–
FALSE
–
[ 50]
QUADRATIC TORQUE
–
INJ BRAKING
ACTIVE [583]
–
FALSE
**0.5 s – [710] DEFLUX TIME
–
**9.0 Hz
–
[577] FREQUENCY
–
100.00 %
–
[578] I-LIM LEVEL
–
**2.0 s
–
[579] DC PULSE
–
**1.0 s
–
[580] FINAL DC PULSE
–
**2.50 %
–
[581] DC LEVEL
–
600.0 s
–
[582] TIMEOUT
–
**100.00 %
–
[739] BASE VOLTS
–
AUTO RESTART
PENDING [608]
–
FALSE
RESTARTING [616]
–
FALSE
ATTEMPTS LEFT [614]
–
5
TIME LEFT [615]
–
10.0 s
FALSE
–
[611] ENABLE
–
5
–
[612] ATTEMPTS
–
10.0 s
–
[610] INITIAL DELAY 1
–
10.0 s
–
[613] ATTEMPT DELAY 1
–
0000
–
[609] TRIGGERS 1
–
0000
[744] T 1
–
0.1 s
–
[678] INITIAL DELAY 2
–
0.1 s
–
[679] ATTEMPT DELAY 2
–
0000 – [677] TRIGGERS 2
–
0000
[745] T 2
–
SLIP COMP
SLIP ACTIVE [762]
–
FALSE
FALSE – [ 82] ENABLE
–
** 1400 n/min
–
[ 83] NAMEPLATE RPM
–
4
–
[ 84] MOTOR POLES
–
** 150.0 n/min
–
[ 85] MOTORING LIMIT
–
** 150.0 n/min
–
[ 86] REGEN LIMIT
–
PID
PID OUTPUT [320]
–
0.00 %
PID ERROR [766]
–
0.00 %
0.00 % – [310] SETPOINT
–
0.00%
–
[764] FEEDBACK
–
FALSE
–
[763] SETPOINT NEGATE
–
FALSE
–
[765] FEEDBACK NEGATE
–
FALSE
–
[311] ENABLE
–
FALSE
–
[312] INTEGRAL DEFEAT
–
1.0
–
[313] P GAIN
–
1.00 s
–
[314] I TIME CONST
–
0.000 s
–
[315] D TIME CONST
–
2.000 s
–
[316] FILTER TC
–
100.00 %
–
[317] OUTPUT POS LIMIT
–
-100.00 %
–
[318] OUTPUT NEG LIMIT
–
1.0000
–
[319] OUTPUT SCALING
–
TEC OPTION
FAULT [756]
–
NONE
VERSION [757]
–
0000
OUTPUT 1 [758]
–
0000
OUTPUT 2 [759]
–
0000
NONE – [750] TYPE
–
0
–
[751] INPUT 1
–
0
–
[752] INPUT 2
–
0
–
[753] INPUT 3
–
0
–
[754] INPUT 4
–
0
–
[755] INPUT 5
–
Macro Control Blocks
Some of these blocks may already be in use by the macros.
Summary of Contents for 605C
Page 16: ...1 4 Getting Started 605C Frequency Inverter ...
Page 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Page 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Page 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Page 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Page 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Page 212: ...13 6 Application Notes 605C Frequency Inverter ...
Page 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Page 236: ......