10-20
Parameter Specification
605C Frequency Inverter
AC Supply Voltage and Power Rating Dependant
Defaults
These parameters (marked with “**” in function block descriptions and macro diagrams) are set
to a value depending on the overall “power-build” of the Inverter indicated by the Product
Code.
400V Build
AC Supply Voltage and
Power Rating Dependant
Defaults
Tag
5.5kW
400V
7.5kW
400V
11kW
400V
FULL LOAD CALIB
64
11.3
14.6
20.0
NO LOAD CALIB
65
6.8
8.1
10.2
STATOR RES
119
3.07
2.55
2.04
LEAKAGE INDUC
120
32.5
27.1
21.6
MUTUAL INDUC
121
292.7
243.7
194.5
MOTOR VOLTS
122
400.0
400.0
400.0
MOTOR CONNECTION
124
DELTA
DELTA
DELTA
POWER FACTOR
242
0.80
0.83
0.86
NAMEPLATE RPM
83
1445
1450
1460
SLIP MOTOR LIMIT
85
82.5
75.0
60.0
SLIP REGEN LIMIT
86
82.5
75.0
60.0
DEFLUX DELAY
100
2.0
2.0
2.0
DEFLUX TIME
710
0.5
0.5
0.5
FLY SEARCH BOOST
32
40.00
40.00
40.00
FLY SEARCH VOLTS
573
9.00
9.00
9.00
FLY SEARCH TIME
574
10.0
10.0
10.0
INJ FREQUENCY
577
9.0
9.0
9.0
INJ DC PULSE
579
2.0
2.0
2.0
INJ FINAL DC
580
1.0
1.0
1.0
INJ DC LEVEL
581
2.50
2.50
2.50
INJ BASE VOLTS
739
100.00
100.00
100.00
ACCEL RATE
258
10.0
10.0
10.0
DECEL RATE
259
10.0
10.0
10.0
SYMMETRIC RATE
267
10.0
10.0
10.0
Summary of Contents for 605C
Page 16: ...1 4 Getting Started 605C Frequency Inverter ...
Page 22: ...2 6 An Overview of the Inverter 605C Frequency Inverter ...
Page 50: ...4 14 Operating the Inverter 605C Frequency Inverter ...
Page 66: ...5 16 The Operator Station 605C Frequency Inverter ...
Page 156: ...8 2 Routine Maintenance and Repair 605C Frequency Inverter ...
Page 184: ...10 22 Parameter Specification 605C Frequency Inverter ...
Page 212: ...13 6 Application Notes 605C Frequency Inverter ...
Page 214: ...14 2 Serial Communications 605C Frequency Inverter ...
Page 236: ......