6-42
DMS-B150L/B210S/B80L/B110S/EX150L/EX210S
6-8. Voltage Selector Setting and Notes
n
Before turning on the power, check the setting of the
voltage selector. If the setting is not correct, the machine
may be damaged.
The voltage selector is set to 240 V at the plant, but its
setting should be changed in some areas.
Set the voltage if required. The following five mode
voltages can be set by the voltage selector.
100 V
For J
120 V
For UC
220 V
For EK
230 V
240 V
1. How to Set the Voltage Selector
n
The voltage selector is installed on the VS-61 board.
1.
Setting the voltage selector
Connect the harness connectors to the connectors of
CN2 to CN6 on the VS-61 board and set the voltage
values.
Input Voltage (V AC)
VS-61 board (CN No.)
100 V
CN2
120 V
CN3
220 V
CN4
230 V
CN5
240 V
CN6
120V
100V
220V
230V
240V
VS-61 board
CN1
CN2
CN3
CN4
CN5
CN6
VS-61 board
6-8. Voltage Selector Setting and Notes