3-1
DMS-B150L/B210S/B80L/B110S/EX150L/EX210S
Section 3
Installation Environment and Machine Mass
For safety and stable performance, use the DMS-B150L/B210S/B80L/B110S/EX150L/EX210S under the
appropriate environment as described below.
The floor on which the console is placed must have at least the specified strength.
3-1. Installation Environment
.
Operation guaranteed temperature : 10
d
C to 30
d
C
.
Relative humidity :
25% to 80% (no condensation)
.
Horizontal tilting of floor :
0.06 degree or less
.
Flatness of floor :
5 mm or less
.
Height of ceiling :
700 mm or higher from the top of the console
.
Strength of floor :
7.5 kN/m
2
or more and 3.5 kN/point or more
(750 kgf/m
2
or more and 350 kgf/point or more)
n
The load per point includes both the load from the caster that is 65 mm in diameter and 38 mm in width,
and the load from the surface that is 56 mm in diameter.
Do not install the consoles in the following locations:
.
Locations subject to high temperatures and high humidity
.
Locations near a heat source
.
Dusty locations
.
Locations subject to vibration
.
Locations with a strong electric or magnetic field
3-2. Mass
Model
Mass per unit
Total mass 1
Total mass 2
Remarks
DMS-B150L
460 kg
645 kg
675 kg
DMS-B210S
465 kg
620 kg
650 kg
DMS-EX150L
200 kg
285 kg
295 kg
DMS-EX210S
195 kg
265 kg
275 kg
DMS-B80L
355 kg
480 kg
545 kg
DMS-B110S
360 kg
470 kg
535 kg
n
The total mass 1 means the maximum mass when cassette tapes and tape drives are installed.
The total mass 2 shows the maximum mass when the Package-supporting equipment such as terminal
server, hub, monitor and AC power cable kits are installed in the total mass 1.