6-56
DMS-B150L/B210S/B80L/B110S/EX150L/EX210S
The relationship between changing the drive installation
areas and the drive setting switches are as follows.
3. Installing the AMP panel
1.
Attach the main panel by aligning the two pins with
the two holes on the top inside the AMP panel.
2.
Fasten the two screws (with drop-safe).
1
2
3
4
5
6
7
8
9
1
2
DMS-B150L /B210S / EX150L /EX210S
DMS-B80L/ B110S
6-10. Setting the Switches
4. Operations after switch setting
After changing the switch setting, renew the PSC setup.
Do the following setting after installation is complete.
1.
Turn on the main power of PetaSite.
2.
Start up the personal computer of the PSC (turn on the
main power) and open the MMT display.
3.
Set the MMT mode to the administrator mode.
4.
Select “Console Composition” from the “Setup” menu
and open the console composition display.
5.
Press the “Load” button to load the new setting.
n
The “Load” button is valid when the drive setting
inside PSC and the drive setting that PetaSite notifies
are not matched. If the “Load” button is not valid even
when the contents of the console composition screen
and the state of the machine are not matched, press the
“Cancel” button to close the display. Wait for a while
and open the console composition screen again.
6.
Press the “Cancel” button to close the display.
After changing the switch setting, the PetaSide main unit
enters the “Full Initial Request” state. Press the INITIAL
key on the display to execute Full Initial.