The SRX-R320 projectors are equipped with 3 signal
processors. They are:
• DVI
The signal processor for externally originated DVI-
D signals.
• HIF
The signal processors for externally originated
HD/DC-SDI signals.
• MB
The signal processor for Media Block originated
signals.
Peltier
1
- Thermal Devices
Use of Peltier devices allows control of the imager
temperature more precisely and results in improved image
consistency. Power to the thermal control devices
associated with the Red, Green, and Blue (R,G,B) imagers
is monitored and the status is shown on this screen.
DVI signal, Ballast, RT Clock Battery
Indicates the status for specific areas on the projector.
• DVI signal
Indicates that the format of an externally applied
DVI-D signal has been verified against the
configuration set using the SRX Controller
application.
• Ballast
Indicates the status of operating conditions of
devices associated with the Lamp Ballast.
• RT Clock Battery
Indicates the status/health of the battery for the Real-
time Clock located in the projector.
Board, Lens, Electrical, AIr FIlter, Filter
Duct
Indicates the status of additional subsystems in the
projector.
The system monitors the number of hours of use of Air
Filters in the system enclosure. The timers for replacement
of these filters are manually reset to zero (0) at the time of
replacement.
Connection and Battery
Indicates statuses related to Marriage processes.
“Connection” indicates the status of physical and logical
network connections between the Media Block and
Projector. “Battery” indicates the status of the Projector’s
Secure Silicon battery.
Lamp Status
The SRX-R320
projectors are single
lamp systems. To access
the Status pane for the
Projector Lamp and
Lens, tap
Menu
, tap
Status
and then tap
Lamp
.
The LAMP pane appears
which displays both
Lamp and Projector
hours of use and the Date
of the most recent Lamp
Replacement.
In addition, Status indicators are present for the following:
• Lamp Timer Alert
• Lamp Ballast
• Lamp Z-Axis
• Luminance Adjustment
• Luminance Adjust Limit
When Projector Components is selected from the Status
Menu the PROJECTOR COMPONENT status
information is displayed.
The STATUS button shown to the right
appears on all Projectionist Terminal
windows and provides immediate access to
1.A Peltier device, is a solid-state active heat pump which
transfers heat from one side of the device to the other side
against the temperature gradient (e.g., from cold to hot),
with consumption of electrical energy. The SRX-R320
does not use a Peltier device.
Tap Lamp
Status Menu
Lamp Information
Lamp Timer Alert
Lamp Ballast
Lamp Z-Axis
Luminance Adjustment
Luminance Adjust Limit
Lamp
Hours
Operation Hours
(Lamp) Replaced
Total Lamp ON
Hours