allowing access to TEST PATTERNS, IMAGE
POSITION, and PICTURE MUTING.
Note that the Current Function is a 3D FUNCTION.
Test Pattern (Select)
A number of Test Patterns are available for use during the
IMAGE POSITION adjustment process. Generally, these
are specific to adjusting the projector for presentation of
3D content. Additional Test Patterns for general projector
alignment are available when the Projection Type is set to
2D.
To select a specific Test Pattern, tap
Test Pattern
on the
ADJUSTMENT pane. The TEST PATTERNS popup
appears. Patterns available are:
• OFF
•
RED1, GREEN1
and
BLUE1 (all 3D)
• GRAY-2 FULL, GRAY-8 FULL and GRAY-10 FULL
(20%, 80% and 100% white, Full Screen)
•
GRAY-8, GRAY-10,
(3D) and
FRAME ADJUST
•
PRISM ADJUST
,
CONVERGENCE ADJUST and
CONTRAST ADJUST
.Insure that
OFF
is
selected when
adjustments are
complete
To select the Test
Pattern image, tap
Menu
, tap
Projector
, tap
Adjustment,
and
then tap
Test
Pattern.
The TEST
PATTERN popup
appears.
Note:
When making a Test Pattern selection, other
Projector Settings remain unchanged but the selected test
pattern appears on the screen.
Insure that
OFF
is selected when adjustments are
complete.
Image Position (3D) Adjustment
Note:
Image Position Adjustments can only be performed
in 3D mode and should not be attempted by anyone not
fully familiar with the process.
Adjusting the image position is a new function related to
support of 3D (stereoscopic) presentation. Image Position
adjustment has been introduced to support alignment of the
right-eye/left-eye images. Access to Image Position is
Role restricted.
Note:
Prior to performing Image Position Adjustment set
the Projector to ON mode, set Projection Type to 3D and
select the appropriate 3D FUNCTION. Allow a minimum
of 30 minutes warm-up to insure that the imaging devices
have reach their operating temperature.
To perform Image Position adjustment, tap
Image
Position
on the ADJUSTMENT pane. The Image Position
Adjustment screen appears.
Adjustments made during the Image Position Adjust
process are applied immediately to the projector. You must
be able to view the auditorium screen in detail as picture
movement is in pixel increments.
1
To realize the Image Position adjustment process, use
the appropriate
Plus
or
Minus
button to
properly position the images as observed on the
auditorium screen.
The adjustment range is;
• L&R eye
Horizontal: -70 to +70
Vertical: -20 to +20 or -120 to +120
Current FUNCTION (3D)
Tap to Access
Test Patterns
Tap to Access
Image Position
Adjustment
Tap to Access
Picture Muting
Tap Desired Pattern
to Select
Tap to Close
Current Function (3D)
Tap +/- to set Horizontal or
Vertical position of both
Right & Left Eye Images
Tap +/- to set Horizontal or
Vertical position of ONLY the
Right Eye Image