8 | Using digital inputs/outputs (optional)
56 / 100
Installation instructions sonnenBatterie 10
Label
Function
Wire cross-section
[mm²]
7
Voltage
[VDC]
Max. amperage
[mA]
1 DO GND
Digital output
0.25–0.75
0
350
2 DO GND
Digital output
0.25–0.75
0
350
3 DO RES
Reserve
0.25–0.75
-
-
4 DO RES
Reserve
0.25–0.75
-
-
5 DO CHP
Digital output
0.25–0.75
24
50
6 DO SCR
Digital output for self-consump-
tion switch
0.25–0.75
24
50
7 DO GEN
Reserve
0.25–0.75
8 DO RES
Reserve
0.25–0.75
-
-
9 DI 24V
Supply voltage for digital inputs
0.25–0.75
24
50
10 DI 24V
Supply voltage for digital inputs
0.25–0.75
24
50
11 DI FLAT
Digital input for sonnenFlat
0.25–0.75
24
50
12 DI CHP
Digital input
0.25–0.75
24
50
13 DI RES
Reserve
0.25–0.75
-
-
14 DI CEI0-21 E
Digital input CEI 0-21 external sig-
nal
0.25–0.75
24
50
15 DI CEI0-21 L
Digital input CEI 0-21 local signal
0.25–0.75
5
25
16 DI CEI0-21 T
Digital input CEI 0-21 remote shut-
off
0.25–0.75
5
25
17 N.C.
Reserve
0.25–0.75
-
-
18 CEI 0-21 GND
0.25–0.75
0
50
19 ATS
Reserve
0.25–0.75
-
-
20 ATS GND
Reserve
0.25–0.75
-
-
Table 4: Technical data for digital inputs (DI) and outputs (DO)
PV red. 1
PV reduction 1
0.25–0.75
)
550
PV red. 2
PV reduction 2
0.25–0.75
)
550
Table 5: Load capacity of relays for PV reduction
8.2 Connecting digital inputs/outputs
8.2.1 Implementing PV reduction
No external relays are needed for PV reduction, as the necessary relays are
already integrated in the central unit of the storage system.
NOTICE
Overloading of relays for PV reduction
Damage to relays on the central unit!
Only load the relays for PV reduction (PV red. 1 and PV red. 2) up to a max-
imum voltage of 60 V (
) and a maximum amperage of 550 mA.
7
When flexible single-conductor wires without end ferrules are used, conductor cross-sections of up to 1.5 mm² are possible.