IMP Commands 3595 4C User Manual Part Two
1-14
35952350 (CH01/AA)
Table 1.7: Mode Codes for IMP type 1H and 1J
Code,
m
Mode Set
Comments
000
Skip
100
101
102
103
104
Volts, dc, auto-ranging.
Volts, dc, 20mV range.
Volts, dc, 200mV range.
Volts, dc, 2V range.
Volts, dc, 10V range.
200
201
202
203
204
800/80
µ
A drive, auto-ranging.
800
µ
A drive, 25
Ω
range.
800
µ
A drive, 250
Ω
range.
800
µ
A drive, 2k5
Ω
range.
80
µ
A drive, 25k
Ω
range.
Three-wire resistance ranges.
,
210
211
212
213
214
800/80
µ
A drive, auto-ranging.
Not Used
Not Used
800
µ
A drive, 1k5
Ω
range.
80
µ
A drive, 25k
Ω
range.
Two-wire resistance ranges.
,
220
221
222
223
224
800/80
µ
A drive, auto-ranging.
Not Used
Not Used
800
µ
A drive, 500
Ω
range.
80
µ
A drive, 25k
Ω
range.
Two-wire resistance ranges.
310 – 314
320 – 324
330 – 334
340 – 344
350 – 354
360 – 364
370 – 374
380 – 384
390 – 394
3A0 – 3A4
Thermocouple, type E.
Thermocouple, type J.
Thermocouple, type K.
Thermocouple, type R.
Thermocouple, type S.
Thermocouple, type T.
Thermocouple, type B.
Thermocouple, type N.
Thermocouple, User TC 1.
Thermocouple, User TC 2.
Same modes as for 1A, 1C and 1E.
The third digit sets the range:
0 = auto-ranging,
4 = least sensitive range (10V).
User defined linearisation. (See UT description in
Section 1.3.7, page 1-45)
400
401
402
403
800
µ
A drive, auto-ranging *.
800
µ
A drive, -200
°
C to -180
°
C
800
µ
A drive, -200
°
C to +400
°
C
800
µ
A drive, -200
°
C to +600
°
C
Four-wire, 100
Ω
, RTD/PRT ranges.
,
410
411
412
413
800
µ
A drive, auto-ranging *.
Do not use
Do not use
800
µ
A drive, -200
°
C to +600
°
C
Three-wire, 100
Ω
, RTD/PRT ranges.
,
(One useful range.)
* Auto-ranges to code 413
420
421
422
423
800
µ
A drive, auto-ranging *.
800
µ
A drive, -200
°
C to -180
°
C
Do not use
Do not use
Four-wire, 100
Ω
, RTD/PRT ranges.
,
(One useful range.)
* Auto-ranges to code 421
430
431
432
433
800
µ
A drive, auto-ranging *.
Do not use
Do not use
800
µ
A drive, -200
°
C to +150
°
C
Three-wire, 100
Ω
, RTD/PRT ranges.
,
(One useful range.)
* Auto-ranges to code 433
,
Three-wire and four-wire resistance and temperature measurements use a pair of channels (connected as shown in
Chapter 12 of the 3595 Series IMP Installation Guide). The channel mode is configured for the odd numbered channel
(e.g. channel 1). Any configuration set-up for the companion even numbered channel (e.g. channel 2) is ignored, but, for
good practice, it is recommended that this channel is configured for ‘skip’ (code 000)
Summary of Contents for 3595 4C
Page 1: ...Precision measurement solutions 3595 4C PC to S Net Interface USER MANUAL 35952350...
Page 2: ...ii 35952350 2001 SOLARTRON MOBREY LIMITED...
Page 6: ...vi 35952350...
Page 7: ......
Page 8: ......
Page 10: ...1 ii 35952350...
Page 12: ...1 iv 35952350...
Page 48: ...Programming the 3595 4C Interface card 3595 4C User Manual Part One 3 20 35952350 CH03 AA...
Page 49: ...3595 4C PC to S Net Interface User Manual PART TWO IMP Commands and Responses...
Page 50: ...2 ii 35952350...
Page 52: ...2 iv 35952350...
Page 108: ...IMP Commands 3595 4C User Manual Part Two 1 56 35952350 CH01 AA...
Page 110: ...Results and Error Formats 3595 4C User Manual Part Two 2 2 35952350 CH02 AA...
Page 122: ...Database Structure 3595 1H and 1J IMP 3595 4C User Manual Part Two A 2 35952350 APPX A AA...
Page 126: ...Database Structure 3595 1H and 1J IMP 3595 4C User Manual Part Two A 6 35952350 APPX A AA...
Page 127: ......