2.1 INTRODUCTION
Table 2.1 summarises the
result formats
applicable to 3595 Series IMP types 1A, 1B, 1C, 1D, 1E, 2A and 2B.
For IMP types 3595 1H and 1J, the same formats apply. However, depending on the
result mode
selected, the results may be time-tagged.
The three result modes of IMP types 3595 1H and 1J are:
•
Real-time
–exactly the same format as for all other IMP types.
•
Time-tagged
–each scan data block, or single measurement result, has a
bookmark
and
time-tag
appended.
•
Historical
– allows the IMP to pass historical time-tagged results back to the Host PC.
The formats of the bytes appended in the
time-tagged
and
historical modes
are described in Sections 2.5
and 2.6.
The error messages that may be returned by any IMP are listed in Section 2.7, together with their
meanings.
Table 2.1: IMP Result Formats
IMP Result
Stream
Format
Scan data of all measurements, except
‘event totalise’ and ‘event increment’.
0
4-byte floating-point number.
(See page 2-5)
Scan data of ‘event totalise’ and ‘event
increment’ measurements.
0
IEEE 754 floating-point number.
(See page 2-4)
Single measurement.
1
4-byte floating-point number.
(See page 2-5)
Events capture.
From 3595 2A and 2B IMP types only)
2
Event capture results are returned in the
form of bookmarks, event tags, event
status, end tags and lost events. Each of
these has an individual format, which is
described in Section 2.4.
IMP status and Command responses
3
ASCII characters.
Response to a SA (SAve set-up data)
command.
0
Command format. (See Chapter 1, ‘IMP
Commands’.)
Summary of Contents for 3595 4C
Page 1: ...Precision measurement solutions 3595 4C PC to S Net Interface USER MANUAL 35952350...
Page 2: ...ii 35952350 2001 SOLARTRON MOBREY LIMITED...
Page 6: ...vi 35952350...
Page 7: ......
Page 8: ......
Page 10: ...1 ii 35952350...
Page 12: ...1 iv 35952350...
Page 48: ...Programming the 3595 4C Interface card 3595 4C User Manual Part One 3 20 35952350 CH03 AA...
Page 49: ...3595 4C PC to S Net Interface User Manual PART TWO IMP Commands and Responses...
Page 50: ...2 ii 35952350...
Page 52: ...2 iv 35952350...
Page 108: ...IMP Commands 3595 4C User Manual Part Two 1 56 35952350 CH01 AA...
Page 110: ...Results and Error Formats 3595 4C User Manual Part Two 2 2 35952350 CH02 AA...
Page 122: ...Database Structure 3595 1H and 1J IMP 3595 4C User Manual Part Two A 2 35952350 APPX A AA...
Page 126: ...Database Structure 3595 1H and 1J IMP 3595 4C User Manual Part Two A 6 35952350 APPX A AA...
Page 127: ......