16. RESECTION MEASUREMENT
82
Standard deviation for the northing and easting
coordinates of each point are displayed in the
Detail tab.
8. If there are problems with the results of a point,
align the cursor with that point and press
[BAD]
.
“BAD” is displayed to the right of the point.
Repeat for all results that include problems.
9. Press
[RE CALC]
to perform calculation again
without the point designated in step 8. The result
is displayed.
If there are no problems with the result, go to step
10.
If problems with the result occur again, perform
the resection measurement from step 3.
• Press
[RE OBS]
to measure the point
designated in step 8.
If no points are designated in step 8, all the
points or only the final point can be observed
again.
• Press
[ADD]
when there is a known point that
has not been measured or when a new known
point is added.
10. Press
[OK]
in <Resection/result> to display
<Resection/Set h angle>.