109
19. MISSING LINE MEASUREMENT
2. Sight the second target, and press
[DIST]
to start
measurement.
Press
[STOP]
to stop measurement.
The following values are displayed:
S : Slope distance of the starting position and
2nd target.
H : Horizontal distance of the starting position
and 2nd position.
V : Height difference of the starting position and
2nd target.
• When measurement data already exists the
screen of step 3 is displayed and measurement
starts.
3. Sight the next target and press
[MLM]
to
begin observation. Slope distance, horizontal
distance and height difference between
multiple points and the starting position can
be measured this way.
• Press
[DIST]
to re-observe the starting
position. Sight the starting position and
press
[DIST]
.
• When
[MOVE]
is pressed, the last target
measured becomes the new starting
position to perform missing line
measurement of the next target.
4.
"19.2 Changing the Starting Point"
5. Press
{ESC}
or tap the cross in the top-right
corner to end missing line measurement.
Results for current point
Results for measurement between starting
position and second target
Summary of Contents for SRX1