123
21. CHANGING THE SETTINGS
• By inputting the temperature and air pressure values, the atmospheric correction value is
calculated and set into the memory. Calculate the atmospheric correction factor as shown in the
following formula.
"30.2 Atmospheric Correction for High Precision Distance Measurement"
•If the weather correction is not required, set the ppm value to 0.
PROCEDURE Recording and editing target information
The
[LIST]
softkey is be displayed when either "Reflector" or "Prism const." is selected in the EDM tab
of <EDM configurations>.
1. Press
[LIST]
to display a list of all recorded
targets.
•
[ADD]
: Displays <Reflector list>. Select the
desired target from this list and press
[OK]
to
add to the list in <Reflector setting>. Up to a
maximum of 6 targets can be recorded.
•
[DEL]
: Deletes the selected target.
ppm = 282.59 -
0.2942 x air pressure (hPa)
1 + 0.003661 x air temperature (°C)