11. TARGET SIGHTING
52
1. Select "Motor" in <Configuration>.
Set Auto Pointing functions in the Configuration
tab.
Set "A.T. Setting" to "Search".
Settings and Options
(*: factory settings)
(1) Accu. search
Fine*/Rapid
(2) A.T. Setting
None/Search*/Track
(3) Srch method
G.S.*/R.C.
Accu. search
Compared to Digital Imaging Mode ("Rapid" setting), the analysis of the prism image in Optical
Imaging Mode ("Fine" setting) is finer and the criteria for completing sighting are more stringent.
"Rapid" mode should be used when supporting the pole by hand if "Time out" is displayed before
the SRX completes sighting as a result of vibration, or, completing Auto Pointing takes too long.
Srch method
Selects search before distance measurement option.
When set to "G.S." the SRX will search for the target in the area specified in the Search area
tab. When set to "R.C.", the SRX will wait for a Turning command to be issued from the RC
Controller before starting Auto Pointing. Both methods can be used to sight the target.
11.1
Auto Pointing Settings
Summary of Contents for SRX1